. 2022 Oct;240(10):2569-2580.
doi: 10.1007/s00221-022-06434-3. Epub 2022 Aug 10.

Microelectrode implants, inflammatory response and long-lasting effects on NADPH diaphorase neurons in the rat frontal cortex

Affiliations

Microelectrode implants, inflammatory response and long-lasting effects on NADPH diaphorase neurons in the rat frontal cortex

Joanilson S Guimaraes et al. Exp Brain Res. 2022 Oct.

Abstract

At present, one of the main therapeutic challenges comprises the development of technologies to improve the life quality of people suffering from different types of body paralysis, through the reestablishment of sensory and motor functions. In this regard, brain-machine interfaces (BMI) offer hope to effectively mitigate body paralysis through the control of paralyzed body parts by brain activity. Invasive BMI use chronic multielectrode implants to record neural activity directly from the brain tissue. While such invasive devices provide the highest amount of usable neural activity for BMI control, they also involve direct damage to the nervous tissue. In the cerebral cortex, high levels of the enzyme NADPH diaphorase (NADPH-d) characterize a particular class of interneurons that regulates neuronal excitability and blood supply. To gain insight into the biocompatibility of invasive BMI, we assessed the impact of chronic implanted tungsten multielectrode bundles on the distribution and morphology of NADPH-d-reactive neurons in the rat frontal cortex. NADPH-d neuronal labeling was correlated with glial response markers and with indices of healthy neuronal activity measured by electrophysiological recordings performed up to 3 months after multielectrode implantation. Chronic electrode arrays caused a small and quite localized structural disturbance on the implanted site, with neuronal loss and glial activation circumscribed to the site of implant. Electrodes remained viable during the entire period of implantation. Moreover, neither the distribution nor the morphology of NADPH-d neurons was altered. Overall, our findings provide additional evidence that tungsten multielectrodes can be employed as a viable element for long-lasting therapeutic BMI applications.

Keywords: Blood supply; Electrophysiology; Histochemistry; Interneurons; Tissue integrity.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Science. 1985 Nov 1;230(4725):561-3 - PubMed
    1. Front Neurosci. 2009 Sep 15;3(2):175-81 - PubMed
    1. Nitric Oxide. 2010 Nov 1;23(3):153-65 - PubMed
    1. PLoS One. 2015 Mar 19;10(3):e0119340 - PubMed
    1. Biomaterials. 2020 Apr;238:119831 - PubMed

LinkOut - more resources