Novel wearable and contactless heart rate, respiratory rate, and oxygen saturation monitoring devices: a systematic review and meta-analysis
- PMID: 35947876
- DOI: 10.1111/anae.15834
Novel wearable and contactless heart rate, respiratory rate, and oxygen saturation monitoring devices: a systematic review and meta-analysis
Abstract
We performed a systematic review and meta-analysis to identify, classify and evaluate the body of evidence on novel wearable and contactless devices that measure heart rate, respiratory rate and oxygen saturations in the clinical setting. We included any studies of hospital inpatients, including sleep study clinics. Eighty-four studies were included in the final review. There were 56 studies of wearable devices and 29 of contactless devices. One study assessed both types of device. A high risk of patient selection and rater bias was present in proportionally more studies assessing contactless devices compared with studies assessing wearable devices (p = 0.023 and p < 0.0001, respectively). There was high but equivalent likelihood of blinding bias between the two types of studies (p = 0.076). Wearable device studies were commercially available devices validated in acute clinical settings by clinical staff and had more real-time data analysis (p = 0.04). Contactless devices were more experimental, and data were analysed post-hoc. Pooled estimates of mean (95%CI) heart rate and respiratory rate bias in wearable devices were 1.25 (-0.31-2.82) beats.min-1 (pooled 95% limits of agreement -9.36-10.08) and 0.68 (0.05-1.32) breaths.min-1 (pooled 95% limits of agreement -5.65-6.85). The pooled estimate for mean (95%CI) heart rate and respiratory rate bias in contactless devices was 2.18 (3.31-7.66) beats.min-1 (pooled limits of agreement -6.71-10.88) and 0.30 (-0.26-0.87) breaths.min-1 (pooled 95% limits of agreement -3.94-4.29). Only two studies of wearable devices measured Sp O2 ; these reported mean measurement biases of 3.54% (limits of agreement -5.65-11.45%) and 2.9% (-7.4-1.7%). Heterogeneity was observed across studies, but absent when devices were grouped by measurement modality and reference standard. We conclude that, while studies of wearable devices were of slightly better quality than contactless devices, in general all studies of novel devices were of low quality, with small (< 100) patient datasets, typically not blinded and often using inappropriate statistical techniques. Both types of devices were statistically equivalent in accuracy and precision, but wearable devices demonstrated less measurement bias and more precision at extreme vital signs. The statistical variability in precision and accuracy between studies is partially explained by differences in reference standards.
Keywords: clinical monitoring; contactless devices; infrared; wearable devices.
© 2022 Association of Anaesthetists.
References
-
- Subbe CP, Duller B, Bellomo R. Effect of an automated notification system for deteriorating ward patients on clinical outcomes. Critical Care 2017; 21: 52.
-
- Sprogis SK, Currey J, Considine J. Patient acceptability of wearable vital sign monitoring technologies in the acute care setting: a systematic review. Journal of Clinical Nursing 2019; 28: 2732-44.
-
- Joshi M, Ashrafian H, Aufegger L, et al. Wearable sensors to improve detection of patient deterioration. Expert Review of Medical Devices 2019; 16: 145-54.
-
- Roche TR, Braun J, Ganter MT, et al. Voice alerting as a medical alarm modality for next-generation patient monitoring: a randomised international multicentre trial. British Journal of Anaesthesia 2021; 127: 769-77.
-
- Harford M, Catherall J, Gerry S, Young JD, Watkinson P. Availability and performance of image-based, non-contact methods of monitoring heart rate, blood pressure, respiratory rate, and oxygen saturation: a systematic review. Physiological Measurement 2019; 40: 06TR1.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous