Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023;36(1):187-198.
doi: 10.3233/BMR-210375.

The accuracy of computerized biophotogrammetry in diagnosing changes in the cervical spine and its reliability for the cervical lordosis angle

The accuracy of computerized biophotogrammetry in diagnosing changes in the cervical spine and its reliability for the cervical lordosis angle

Priscila Maria Nascimento Martins de Albuquerque et al. J Back Musculoskelet Rehabil. 2023.

Abstract

Background: Accuracy studies of biophotogrammetry protocols require standardization similar to radiography.

Objective: To estimate the diagnostic accuracy of a biophotogrammetric assessment protocol for cervical hyperlordosis, compared to radiography, and its intra- and inter-examiner reliability for measuring the cervical lordosis angle.

Methods: A study of diagnostic accuracy in women complaining of cervical pain. Two photos were taken using the CorelDraw biophotogrammetric protocol and one radiograph using the Cobb C1-C7 method. The Intra- and Inter-examiner reliability was calculated using the Kappa index and the intraclass correlation coefficient (ICC). The Bland-Altman plot and the ROC curve were presented.

Results: The sample consisted of 19 women. The accuracy of biophotogrammetry was 94.73% and the reliability between biophotogrammetry and radiography presented an ICC of 0.84 and a Kappa of 0.87. The excellent intra (ICC = 0.94) and inter-examiner (ICC = 0.86) reliability of the biophotogrammetry was confirmed. The area under the ROC curve was 93.5%. The Bland-Altman plot indicated differences between the two instruments close to the mean (1.5∘).

Conclusion: The biophotogrammetric protocol proved to be accurate in diagnosing cervical hyperlordosis, with excellent reliability between the biophotogrammetric and radiographic assessments. It also demonstrated excellent intra- and inter-examiner reliability in measuring the cervical lordosis angle.

Keywords: Cervical vertebrae; data accuracy; photogrammetry; posture; radiography.