Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2022 Sep:97:165-173.
doi: 10.1016/j.gaitpost.2022.08.002. Epub 2022 Aug 6.

Validity of the activPAL monitor to measure stepping activity and activity intensity: A systematic review

Affiliations

Validity of the activPAL monitor to measure stepping activity and activity intensity: A systematic review

Yanlin Wu et al. Gait Posture. 2022 Sep.

Abstract

Background: Accumulating step counts and engaging in moderate-to-vigorous intensity physical activity is positively associated with numerous health benefits. The activPAL is a thigh-worn monitor that is frequently used to measure physical activity.

Research question: Can the activPAL accurately measure stepping activity and identify physical activity intensity?

Methods: We systematically reviewed validation studies examining the accuracy of activPAL physical activity outcomes relative to a criterion measure in adults (>18 years). Citations were not restricted to language or date of publication. Sources were searched up to May 16, 2021 and included Scopus, EMBASE, MEDLINE, CINAHL, and Academic Search Premier. The study was pre-registered in Prospero (ID# CRD42021248240). Study quality was determined using a modified Hagströmer Bowles checklist.

Results: Thirty-nine studies (20 laboratory arms, 17 semi-structured arms, 11 uncontrolled protocol arms; 1272 total participants) met the inclusion criteria. Most studies demonstrated a high validity of the activPAL to measure steps across laboratory (12/15 arms), semi-structured (10/13 arms) and uncontrolled conditions (5/7 arms). Studies that demonstrated low validity were generally conducted in unhealthy populations, included slower walking speeds, and/or short walking distances. Few studies indicated that the activPAL accurately measured physical activity intensity across laboratory (0/6 arms), semi-structured (0/5 arms) and uncontrolled conditions (2/5 arms). Using the default settings, the activPAL overestimates light-intensity activity but underestimates moderate-to-vigorous intensity activity. The overall study quality was 11.5 ± 2.0 out of 19.

Conclusion: Despite heterogeneous methodological and statistical approaches, the included studies generally provide supporting evidence that the activPAL can accurately detect stepping activity but not physical activity intensity. Strategies that use alternative data processing methods have been developed to better characterize physical activity intensity, but all methods still underestimate vigorous-intensity activity.

Keywords: Activity intensity; Energy expenditure; Inclinometer; Stepping; Thigh-worn accelerometry.

PubMed Disclaimer

Conflict of interest statement

Conflict of interest All authors declare no conflict of interest.

Publication types

Grants and funding

LinkOut - more resources