Tricuspid Regurgitation Related to Cardiac Implantable Electronic Devices: An Integrative Review
- PMID: 35964911
- DOI: 10.1016/j.echo.2022.08.004
Tricuspid Regurgitation Related to Cardiac Implantable Electronic Devices: An Integrative Review
Abstract
The use of cardiac implantable electronic devices, including permanent pacemakers, implantable cardiac defibrillators, and cardiac resynchronization therapy, has dramatically increased in recent years. The interaction between the device lead and tricuspid valve leaflets is a potential cause of tricuspid regurgitation that in turn has an impact on morbidity and mortality. Echocardiography is necessary to grade tricuspid regurgitation severity. The use of three-dimensional imaging helps determine whether the device lead is interfering with normal leaflet coaptation. Early identification of lead-related tricuspid regurgitation is critical to select the optimal treatment, which may include lead extraction or even tricuspid valve repair or replacement in severe cases. The aims of this review are to provide a thorough assessment of the evidence about lead-associated tricuspid regurgitation and the benefits of using three-dimensional echocardiography with some technical considerations and to propose a treatment algorithm.
Keywords: 3D echocardiography; Artificial cardiac pacing; Device lead; Right ventricular dysfunction; Tricuspid regurgitation.
Copyright © 2022 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
Similar articles
-
3D echocardiographic location of implantable device leads and mechanism of associated tricuspid regurgitation.JACC Cardiovasc Imaging. 2014 Apr;7(4):337-47. doi: 10.1016/j.jcmg.2013.11.007. Epub 2014 Mar 13. JACC Cardiovasc Imaging. 2014. PMID: 24631508
-
Severe tricuspid regurgitation due to interactions with right ventricular permanent pacemaker or defibrillator leads.Pacing Clin Electrophysiol. 2018 Jul;41(7):845-853. doi: 10.1111/pace.13369. Epub 2018 Jun 4. Pacing Clin Electrophysiol. 2018. PMID: 29757467 Review.
-
Cardiac Implantable Electronic Device Lead-Induced Tricuspid Regurgitation.JACC Cardiovasc Imaging. 2019 Apr;12(4):622-636. doi: 10.1016/j.jcmg.2018.09.028. JACC Cardiovasc Imaging. 2019. PMID: 30947905 Review.
-
Clinical utility of three-dimensional echocardiography in the evaluation of tricuspid regurgitation induced by implantable device leads.Echocardiography. 2016 Nov;33(11):1689-1696. doi: 10.1111/echo.13314. Epub 2016 Aug 19. Echocardiography. 2016. PMID: 27539645
-
Tricuspid Valve Dysfunction Following Pacemaker or Cardioverter-Defibrillator Implantation.J Am Coll Cardiol. 2017 May 9;69(18):2331-2341. doi: 10.1016/j.jacc.2017.02.055. J Am Coll Cardiol. 2017. PMID: 28473139 Review.
Cited by
-
The Use of 3D-Echo in Edge-to-Edge Percutaneous Tricuspid Valve Repair.J Clin Med. 2025 Jan 22;14(3):684. doi: 10.3390/jcm14030684. J Clin Med. 2025. PMID: 39941355 Free PMC article. Review.
-
An Integrative, Multiparametric Approach to Tricuspid Regurgitation Evaluation: A Case-Based Illustration.JACC Case Rep. 2023 Oct 5;25:102050. doi: 10.1016/j.jaccas.2023.102050. eCollection 2023 Nov 1. JACC Case Rep. 2023. PMID: 38094205 Free PMC article.
-
Incidence, Risk Factors, and Outcomes Associated With Permanent Pacemaker Implantation Following Tricuspid Valve Surgery.J Am Heart Assoc. 2024 Feb 6;13(3):e032760. doi: 10.1161/JAHA.123.032760. Epub 2024 Jan 31. J Am Heart Assoc. 2024. PMID: 38293932 Free PMC article.
-
How To Perform Comprehensive Transthoracic Echocardiography?Acta Cardiol Sin. 2025 Jan;41(1):50-54. doi: 10.6515/ACS.202501_41(1).20241128A. Acta Cardiol Sin. 2025. PMID: 39776928 Free PMC article. No abstract available.
-
Tricuspid Regurgitation (TR) after Implantation of a Cardiac Implantable Electronic Device (CIED)-One-Year Observation of Patients with or without Left Ventricular Dysfunction.J Cardiovasc Dev Dis. 2023 Aug 19;10(8):353. doi: 10.3390/jcdd10080353. J Cardiovasc Dev Dis. 2023. PMID: 37623367 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical