Infrared lasers may provide faster and more precise sealing of blood vessels and with lower jaw temperatures than ultrasonic and electrosurgical devices. This study explores an oscillating or reciprocating side-firing optical fiber method for transformation of a circular laser beam into a linear beam, necessary for integration into a standard 5-mm-diameter laparoscopic device, and for uniform irradiation perpendicular to the vessel length. A servo motor connected to a side-firing, 550-μm-core fiber, provided linear translation of a 2.0-mm-diameter circular beam over either 5 mm or 11 mm scan lengths for sealing small or large vessels, respectively. Laser seals were performed, ex vivo, on a total of 20 porcine renal arteries of 1-6 mm diameter (n = 10 samples for each scan length). Each vessel was compressed to a fixed 0.4-mm-thickness, matching the 1470-nm laser optical penetration depth. Vessels were irradiated with fluences ranging from 636 J/cm2 to 716 J/cm2. A standard burst pressure (BP) setup was used to evaluate vessel seal strength. The reciprocating fiber produced mean BP of 554 ± 142 and 524 ± 132 mmHg, respectively, and consistently sealing blood vessels, with all BP above hypertensive (180 mmHg) blood pressures. The reciprocating fiber provides a relatively uniform linear beam profile and aspect ratio, but will require integration of servo motor into a handpiece.
Keywords: blood vessel; burst pressures; coagulation; compression; laser; optical fiber; sealing.
Figures






References
-
- Reccia I, Kumar J, Kusano T, Zanellato A, Draz A, Spalding D, Habib N, and Pai M, “A systematic review on radiofrequency assisted laparoscopic liver resection: Challenges and window to excel,” Surg. Oncol 26(3), 296–304 (2017). - PubMed
-
- Tanaka R, Gitelis M, Meiselman D, Abar B, Zapf M, Carbray J, Vigneswaran Y, Cheng JC, and Ujiki M, “Evaluation of vessel sealing performance among ultrasonic devices in a porcine model,” Surg. Innov 22(4), 338–343 (2015). - PubMed
-
- Manasia P, Alcaraz A, and Alcover J, “Ligasure vs. sutures in bladder replacement with Montie ileal neobladder after radical cystectomy,” Arch. Ital. Urol. Androl 75(4), 199–201 (2003). - PubMed
-
- Romano F, Gelmini R, Caprotti R, Andreotti A, Guaglio M, Franzoni C, Uggeri F, and Saviano M, “Laparoscopic splenectomy: ligasure versus EndoGIA: a comparative study,” J. Laparoendosc. Adv. Surg. Tech. A 17(6), 763–767, (2007). - PubMed
Grants and funding
LinkOut - more resources
Full Text Sources