Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Case Reports
. 2022 May 29:14:39-42.
doi: 10.1016/j.xjtc.2022.05.016. eCollection 2022 Aug.

Pseudoaneurysm due to stentgraft-graft anastomosis failure: A case report

Affiliations
Case Reports

Pseudoaneurysm due to stentgraft-graft anastomosis failure: A case report

Yuki Wada et al. JTCVS Tech. .
No abstract available

PubMed Disclaimer

Figures

None
Aortography revealed extravasation of contrast media from stentgraft–graft anastomosis.
Figure 1
Figure 1
A, The prosthetic graft was anastomosed directly to the stentgraft with the aortic wall using a 4-0 monofilament and a peripheral felt strip. B, Postoperative computed tomography image.
Figure 2
Figure 2
A-C, Preoperative contrast-enhanced computed tomography showed the presence of a pseudoaneurysm and extravasation (arrow) at the anastomosis site. D, Aortography before stentgraft implantation revealed extravasation (arrow) at the anastomosis site. E, Stent graft was implanted at the anastomosis site. F, Aortography after stentgraft implantation showed no residual extravasation.

Similar articles

Cited by

References

    1. Gomibuchi T., Takano T., Wada Y., Terasaki T., Seto T., Fukui D. Pseudoaneurysm of graft-graft anastomosis of a hand-sewn branched graft: a case report. J Cardiothorac Surg. 2015;10:152. - PMC - PubMed
    1. Folkmann S., Weiss G., Pisarik H., Czerny M., Grabenwoger M. Thoracoabdominal aortic aneurysm repair after frozen elephant trunk procedure. Eur J Cardiothorac Surg. 2015;47:115–119. - PubMed
    1. Tanaka K., Makuuchi H., Naruse Y., Kobayashi T., Hayashi I., Takayama T., et al. False aneurysm due to suture loosening after aortic arch replacement. Asian Cardiovasc Thorac Ann. 2002;10:346–348. - PubMed
    1. Kabasawa M., Takahara Y., Mogi K., Hatakeyama M. A case of surgical treatment for pseudoaneurysm 19 years after aortic root replacement. Jpn J Cardiovasc Surg. 2008;37:268–271.
    1. Gaspar M.R., Movius H.J., Rosental J.J., Bell D.D., Lemire G.G., Odou M. Prolene sutures are not a significant factor in anastomotic false aneurysms. Am J Surg. 1983;146:216–219. - PubMed

Publication types

LinkOut - more resources