Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 Jan;64(1):86-94.
doi: 10.1111/vru.13134. Epub 2022 Aug 15.

Rapid brain MRI protocols result in comparable differential diagnoses versus a full brain protocol in most canine and feline cases

Affiliations

Rapid brain MRI protocols result in comparable differential diagnoses versus a full brain protocol in most canine and feline cases

Kelsey A Johnson et al. Vet Radiol Ultrasound. 2023 Jan.

Abstract

Evaluation of brain disease in veterinary patients uses a wide variety of MRI sequences. A shortened protocol that maintains consistency of interpretation would reduce radiologist reporting time, patient anesthetic time, and client cost. The aims of this retrospective, methods comparison, observer agreement study were to evaluate whether abbreviated MRI protocols alter differential diagnoses and recommendations compared to our institution's standard protocol; evaluate interobserver agreement on standard brain MRIs; and assess whether differential diagnoses change after postcontrast images. Normal and pathologic canine and feline brain MRIs were retrieved from hospital archives. Three protocols were created from each: a 5-sequence noncontrast enhanced Fast Brain Protocol 1 (FBP1); a 6-sequence contrast-enhanced Fast Brain Protocol 2 (FBP2); and an 11-sequence standard brain protocol (SBP). Three blinded veterinary radiologists interpreted FBP images for 98 cases (1 reader/case) and SBP images for 20 cases (3 readers/case). A fourth observer compared these interpretations to the original MRI reports (OMR). Overall agreement between FBPs and OMR was good (k = 0.75) and comparable to interobserver agreement for multiple reviews of SBP cases. Postcontrast images substantially altered conclusions in 17/97 cases (17.5%), as well as improved interobserver agreement compared to noncontrast studies. The conclusions reached with shortened brain protocols were comparable to those of a full brain study. The findings supported the use of a 6-sequence brain MRI protocol (sagittal T2-weighted [T2w] TSE; transverse T2w turbo spin echo fluid-attenuated inversion recovery, T2*-weighted gradient recalled echo, T1-weighted spin echo, and diffusion weighted imaging/apparent diffusion coefficient; and postcontrast transverse T1-weighted spin echo) for dogs and cats with suspected intracranial disease.

Keywords: agreement; canine; fast protocol; feline; neuroimaging.

PubMed Disclaimer

Similar articles

Cited by

References

REFERENCES

    1. Robertson I. Optimal magnetic resonance imaging of the brain. Vet Radiol Ultrasound. 2011;52(s1):S15-S22. doi:10.1111/j.1740-8261.2010.01781.x
    1. Mikulis DJ, Roberts T, Neuro MR. Protocols. J Magn Reson Imaging. 2007;26(4):838-847. doi:10.1002/jmri.21041
    1. Parizel PM, van den Hauwe L, De Belder F. Magnetic Resonance Imaging of the Brain. In: Reimer P, Parizel PM, Meaney JFM, Stichnoth FA, eds. Clinical MR Imaging. Springer; 2010;107-195. doi:10.1007/978-3-540-74504-4_2
    1. Roberts T, Mikulis D, Neuro MR. Principles. J Magn Reson Imaging. 2007;26(4):823-837. doi:10.1002/jmri.21029
    1. Leclerc M-KK, d'Anjou M-AA, Blond L, et al. Interobserver agreement and diagnostic accuracy of brain magnetic resonance imaging in dogs. J Am Vet Med Assoc. 2013;242(12):1688-1695. doi:10.2460/javma.242.12.1688

LinkOut - more resources