Limb-length discrepancy measured with computerized axial tomographic equipment
- PMID: 3597470
Limb-length discrepancy measured with computerized axial tomographic equipment
Abstract
A simple, rapid, and accurate method for measuring limb-length discrepancies with computerized axial tomographic equipment is described. With this method less irradiation is delivered and some of the errors of computation are eliminated, compared with conventional methods. The costs of the technique are comparable with those of scanograms. The method is particularly applicable in the patient who has contracture of a joint.
Similar articles
-
Comparison of orthoroentgenography and computed tomography in the measurement of limb-length discrepancy.J Bone Joint Surg Am. 1992 Jul;74(6):897-902. J Bone Joint Surg Am. 1992. PMID: 1634580
-
CT scanograms for measuring leg length discrepancy.Radiology. 1984 Jun;151(3):802. doi: 10.1148/radiology.151.3.6718746. Radiology. 1984. PMID: 6718746
-
Leg length determination by CT digital radiography.AJR Am J Roentgenol. 1985 Mar;144(3):613-5. doi: 10.2214/ajr.144.3.613. AJR Am J Roentgenol. 1985. PMID: 3871572
-
Avoiding Hip Instability and Limb Length Discrepancy After Total Hip Arthroplasty.Orthop Clin North Am. 2016 Apr;47(2):327-34. doi: 10.1016/j.ocl.2015.09.006. Orthop Clin North Am. 2016. PMID: 26772941 Review.
-
Techniques and applications of automatic tube current modulation for CT.Radiology. 2004 Dec;233(3):649-57. doi: 10.1148/radiol.2333031150. Epub 2004 Oct 21. Radiology. 2004. PMID: 15498896 Review.
Cited by
-
Methods for assessing leg length discrepancy.Clin Orthop Relat Res. 2008 Dec;466(12):2910-22. doi: 10.1007/s11999-008-0524-9. Epub 2008 Oct 4. Clin Orthop Relat Res. 2008. PMID: 18836788 Free PMC article.
-
Computed Tomography in Limb Salvage and Deformity Correction-3D Assessment, Indications, Radiation Exposure, and Safety Considerations.J Clin Med. 2021 Aug 24;10(17):3781. doi: 10.3390/jcm10173781. J Clin Med. 2021. PMID: 34501227 Free PMC article.
-
The Comparison of Lower Extremity Length and Angle between Computed Radiography-Based Teleoroentgenogram and EOS® Imaging System.Diagnostics (Basel). 2022 Apr 22;12(5):1052. doi: 10.3390/diagnostics12051052. Diagnostics (Basel). 2022. PMID: 35626207 Free PMC article.
-
Measurement of leg length discrepancy after total hip arthroplasty. The reliability of a plain radiographic method compared to CT-scanogram.Skeletal Radiol. 2012 Feb;41(2):187-91. doi: 10.1007/s00256-011-1166-7. Epub 2011 Apr 14. Skeletal Radiol. 2012. PMID: 21491155
-
Leg length discrepancy in total hip arthroplasty: comparison of two methods of measurement.Int Orthop. 2009 Oct;33(5):1189-93. doi: 10.1007/s00264-008-0633-9. Epub 2008 Aug 2. Int Orthop. 2009. PMID: 18677480 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical