Evaluation of Erythrocytes Magnetized Technology for Measurement of ABO Isoagglutinin Titers
- PMID: 35982875
- PMCID: PMC9381308
- DOI: 10.1055/s-0041-1732808
Evaluation of Erythrocytes Magnetized Technology for Measurement of ABO Isoagglutinin Titers
Abstract
Background A variation in the measurement of ABO antibody titer has been seen among different laboratories due to lack of standardization. In our study, we aim to evaluate automated ABO isoagglutinin titer measurements by erythrocytes magnetized technology (EMT) and compare with conventional tube technique (TT). Methods We performed ABO isoagglutinin titration on samples received in a reference laboratory during a period of 2 months. A total of 134 tests for immunoglobulin G (IgG) titer and 116 for immunoglobulin M (IgM) for anti-A or anti-B were included in the study. Samples were processed for ABO isoagglutination titers by both TT and EMT by QWALYS-3 (DIAGAST, France). Microsoft Excel was used to compile data, for all calculations, and to draw graphs and plots. The number and percentage of cases within ±1, ±2, or ±3 titer difference (TT-EMT) were calculated. Results Median titers and their ranges obtained by EMT were higher or equal to those by TT for all IgM and IgG ABO-antibodies in all blood group (BGs), except anti-A IgM in (BG) O that was lower by EMT (32 [4:128]) than TT (48 [8:256]). One twenty one (121/134, 90.3%) cases of IgG titer showed an agreement by both methods (within ± one titer difference). One hundred seven cases (107/116, 92.2%) for IgM titer were within one titer difference by both the methods. Conclusion Results of titration by EMT-based automated instrument QWALYS-3 and conventional TT may vary by one titer dilution in the majority of cases. Use of consistent method for patient management is, therefore, advised.
Keywords: QWALYS-3; conventional tube technique; erythrocytes magnetized technology; isoagglutinin titer.
The Indian Association of Laboratory Physicians. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/).
Conflict of interest statement
Conflicts of Interest None.
Figures



Similar articles
-
Comparison of ABO isoagglutinin titres by three different methods: tube haemagglutination, micro-column agglutination and automated immunohematology analyzer based on erythrocyte-magnetized technology.Vox Sang. 2020 Apr;115(3):233-240. doi: 10.1111/vox.12878. Epub 2019 Dec 26. Vox Sang. 2020. PMID: 31877575
-
A prospective observational study to evaluate effect of heat inactivation on ABO titers performed by column agglutination technology and conventional tube technique.Asian J Transfus Sci. 2023 Jan-Jun;17(1):41-47. doi: 10.4103/ajts.ajts_175_20. Epub 2023 Mar 1. Asian J Transfus Sci. 2023. PMID: 37188029 Free PMC article.
-
Comparative evaluation of the conventional tube test and column agglutination technology for ABO antibody titration in healthy individuals: a report from India.Immunohematology. 2021 Mar;37(1):25-32. doi: 10.21307/immunohematology-2021-006. Immunohematology. 2021. PMID: 33962486
-
ABO-incompatible kidney transplantation can be successfully conducted by monitoring IgM isoagglutinin titers during desensitization.Transfusion. 2020 Mar;60(3):598-606. doi: 10.1111/trf.15672. Epub 2020 Jan 20. Transfusion. 2020. PMID: 31957888
-
Laboratory support of ABO antibody monitoring for ABO-incompatible solid organ transplantation.Korean J Transplant. 2022 Jun 30;36(2):99-103. doi: 10.4285/kjt.22.0011. Epub 2022 May 24. Korean J Transplant. 2022. PMID: 35919194 Free PMC article. Review.
References
-
- Daniels G, Bromilow I.Essential Guide to Blood Groups 3rd editionChichesterWest Sussex, UK: Wiley Blackwell; 2014132
-
- Li P, Pang L H, Liang H F, Chen H Y, Fan X J. Maternal IgG anti-A and anti-B titer levels screening in predicting ABO hemolytic disease of the newborn: a meta-analysis. Fetal Pediatr Pathol. 2015;34(06):341–350. - PubMed
-
- Shimmura H, Tanabe K, Ishikawa N, Tokumoto T, Takahashi K, Toma H. Role of anti-A/B antibody titers in results of ABO-incompatible kidney transplantation. Transplantation. 2000;70(09):1331–1335. - PubMed
-
- Tobian A A, Shirey R S, Montgomery R A et al.ABO antibody titer and risk of antibody-mediated rejection in ABO-incompatible renal transplantation. Am J Transplant. 2010;10(05):1247–1253. - PubMed
-