Patent Foramen Ovale and Ascending Aortic Dilatation Causing Platypnea-Orthodeoxia Syndrome
- PMID: 35989814
- PMCID: PMC9381869
- DOI: 10.7759/cureus.26953
Patent Foramen Ovale and Ascending Aortic Dilatation Causing Platypnea-Orthodeoxia Syndrome
Abstract
Platypnea-orthodeoxia syndrome (POS) is an underdiagnosed clinical syndrome characterized by dyspnea (platypnea) and hypoxemia (orthodeoxia) in the upright position that resolves when recumbent. POS is often due to an underlying right-to-left shunt. Four broad mechanisms for the shunt have been described: intracardiac shunts, intrapulmonary shunts, hepatopulmonary syndrome, and pulmonary ventilation-perfusion mismatch. A 68-year-old male with a past medical history of chronic obstructive pulmonary disease (COPD), obstructive sleep apnea, ascending aortic dilation (3.9 cm), myelofibrosis, and status post stem cell transplant complicated by graft versus host disease was found hypoxemic (oxygen saturation: 82%) on routine visit prompting hospitalization. Hypoxemia initially responded to 40% FiO2 but subsequently progressed to refractory hypoxemia on 100% FiO2. A chest computed tomography (CT) scan showed evidence of multiple segmental pulmonary emboli with patent central pulmonary arteries. Hypoxemia out of proportion to pulmonary embolism clot burden and examination findings consistent with orthodeoxia prompted further investigations. Nuclear medicine scan showed radiotracer activity in both brain and kidneys consistent with a small right-to-left shunt (5.9%). Transesophageal echocardiography (TEE) revealed a patent foramen ovale (PFO) with a right-to-left shunt across the atrial septum, with a maximum opening of 3.5 mm and tunnel length of 25 mm. Right heart catheterization (RHC) is consistent with the right-to-left shunt and normal right heart pressures. The degree of the shunt was not significant enough to explain the degree of hypoxemia, but all the diagnostic studies were performed in a supine position, possibly underestimating the degree of the shunt. PFO closure with transcatheter 30-mm Gore device (GORE® CARDIOFORM, Arizona, USA) decreased supplemental oxygen requirement from 75% high-flow nasal cannula (NC) to room air (RA) immediately after the procedure. The patient was subsequently discharged home on a baseline oxygen requirement of 2 L NC at nighttime. POS should be suspected when a patient develops severe hypoxemia after changing from a recumbent position to a sitting or standing position. The identification and correction of the shunting or mismatch often allow complete resolution of POS. Transthoracic echocardiography with agitated saline, TEE, and RHC are the diagnosis modalities of choice. Left heart cardiac catheterization remains the gold standard, which would demonstrate a mismatch in oxygen saturation between the pulmonary vein and the aorta. Our patient's PFO was successfully closed by a percutaneous transcatheter closure device leading to the complete resolution of hypoxemia immediately.
Keywords: hypoxemia; orthodeoxia; patent foramen ovale; platypnea; right-to-left shunting.
Copyright © 2022, Ahmed et al.
Conflict of interest statement
The authors have declared that no competing interests exist.
Figures
Similar articles
-
A patient with unexplained hypoxemia after a fall diagnosed with platypnea orthodeoxia syndrome: approaches to resolving discrepancies between level of hypoxemia and clinical presentation.Can J Anaesth. 2024 Nov;71(11):1558-1564. doi: 10.1007/s12630-024-02854-7. Epub 2024 Oct 28. Can J Anaesth. 2024. PMID: 39467992 English.
-
Platypnea-orthodeoxia syndrome in the elderly treated by percutaneous patent foramen ovale closure: a case series and literature review.Eur J Intern Med. 2013 Dec;24(8):813-7. doi: 10.1016/j.ejim.2013.08.698. Epub 2013 Sep 3. Eur J Intern Med. 2013. PMID: 24007641 Review.
-
The effect of patent foramen ovale closure in patients with platypnea-orthodeoxia syndrome.Catheter Cardiovasc Interv. 2015 Oct;86(4):701-7. doi: 10.1002/ccd.25953. Epub 2015 Jun 9. Catheter Cardiovasc Interv. 2015. PMID: 26063336
-
Persistent hypoxemia and platypnea-orthodeoxia after left single-lung transplantation: a case report.J Med Case Rep. 2015 Jun 12;9:138. doi: 10.1186/s13256-015-0598-4. J Med Case Rep. 2015. PMID: 26065882 Free PMC article.
-
Platypnea-Orthodeoxia Syndrome: To Shunt or Not to Shunt, That is the Question.Tex Heart Inst J. 2016 Jun 1;43(3):264-6. doi: 10.14503/THIJ-15-5280. eCollection 2016 Jun. Tex Heart Inst J. 2016. PMID: 27303248 Free PMC article. Review.
Cited by
-
When hypoxemia does not respond to oxygen therapy: a case of platypnea-orthodeoxia syndrome.Arch Cardiol Mex. 2024 Oct 24;95(2):235-8. doi: 10.24875/ACM.24000091. Online ahead of print. Arch Cardiol Mex. 2024. PMID: 39447541 Free PMC article.
References
-
- Platypnea-orthodeoxia syndrome: etiology, differential diagnosis, and management. Cheng TO. Catheter Cardiovasc Interv. 1999;47:64–66. - PubMed
-
- Acute hypoxia due to right to left blood shunting in a patient with atrial septal defect. Solar M, Fridrich J, Ceral J, Borovec M. Resuscitation. 2007;74:382–385. - PubMed
-
- Platypnea and orthodeoxia in a patient with pulmonary embolism. Salvetti M, Zotti D, Bazza A, et al. Am J Emerg Med. 2013;31:760–762. - PubMed
Publication types
LinkOut - more resources
Full Text Sources
Miscellaneous