Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2022 Nov 15:216:114630.
doi: 10.1016/j.bios.2022.114630. Epub 2022 Aug 17.

Electrochemical detection of Zika and Dengue infections using a single chip

Affiliations

Electrochemical detection of Zika and Dengue infections using a single chip

Isabella Sampaio et al. Biosens Bioelectron. .

Abstract

Zika and Dengue are infectious diseases caused by flaviviruses and transmitted by Aedes mosquitoes. Although symptoms are usually mild, complications such as dengue hemorrhagic fever and microcephaly in newborns -after the pregnant woman becomes infected with the Zika virus-have emerged as a global public health concern. The co-circulation of Zika and Dengue viruses and the overlapping of their symptoms represent a challenge for the accurate diagnosis. A single test for the point-of-care detection of both diseases is crucial. Here we report a single chip that distinguishes between Zika and Dengue infections using the non-structural protein 1 (NS1) as biomarkers. A novel multiplex electrochemical device containing four independent working electrodes was developed. Zika and Dengue biosensors were fabricated separately on different working electrodes. Selectivity tests showed that the two biosensors can distinguish not only the NS1 proteins from Zika and Dengue but also the spike proteins present in the SARS-CoV-2. This is especially relevant as patients with COVID-19 may have symptoms similar to Zika and Dengue. The gold surface was modified with cysteamine and antibodies against the NS1 proteins. Both biosensors detected their respective biomarkers at clinically relevant concentrations and presented a good linear relationship between the percentage change in impedance and the logarithm of the NS1 concentration (R2 = 0.990 for Dengue and R2 = 0.995 for Zika). Upon combining a simple sample preparation with a portable detection method, our disposable multiplex device offers a point-of-care diagnostic test for Zika and Dengue using a single chip. Additionally, two other biosensors can be added to the chip, providing a platform for viral detection.

Keywords: Dengue detection; Electrochemical biosensor; Multiplex device; SARS-CoV-2; Simultaneous detection; Zika detection.

PubMed Disclaimer

Conflict of interest statement

Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Similar articles

Cited by

LinkOut - more resources