Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2022 Aug 4;12(8):1897.
doi: 10.3390/diagnostics12081897.

Reliability and Construct Validity of the Yale Pharyngeal Residue Severity Rating Scale: Performance on Videos and Effect of Bolus Consistency

Affiliations

Reliability and Construct Validity of the Yale Pharyngeal Residue Severity Rating Scale: Performance on Videos and Effect of Bolus Consistency

Sara Rocca et al. Diagnostics (Basel). .

Abstract

The Yale Pharyngeal Residue Severity Rating Scale (YPRSRS) provides an image-based assessment of pharyngeal residue in the fiberoptic endoscopic evaluation of swallowing (FEES). Its performance was investigated only in FEES frames. This study analyzed the reliability and construct validity of the YPRSRS in FEES videos and the influence of bolus consistency. Thirty pairs of FEES videos and frames, 8 thin liquids (<50 mPa·s), 11 pureed (2583.3 mPa·s at 50 s−1, 697.87 mPa·s at 300 s−1), and 11 solid food; were assessed by 29 clinicians using the YPRSRS; 14 raters re-assessed materials at least 15 days from the first evaluation. Construct validity and intra-rater reliability were assessed using weighted Cohen’s Kappa. Inter-rater reliability was assessed using weighted Fleiss Kappa. Construct validity and inter-rater reliability were almost perfect or excellent for frames (0.82 ≤ k ≤ 0.89) and substantial or intermediate to good for videos (0.67 ≤ k ≤ 0.79). Intra-rater reliability was almost perfect for both frames and videos (k ≥ 0.84). Concerning bolus consistency, thin liquids had significantly lower values of construct validity, intra-, and inter-rater reliability than pureed and solid food. Construct validity and inter-rater reliability were significantly lower for solid food than for pureed food. The YPRSRS showed satisfactory reliability and construct validity also in FEES videos. Reliability was significantly influenced by bolus consistency.

Keywords: deglutition disorders; fiberoptic endoscopic evaluation of swallowing; reliability.

PubMed Disclaimer

Conflict of interest statement

The authors declare no conflict of interest.

Similar articles

Cited by

References

    1. Logemann J.A. The evaluation and treatment of swallowing disorders. Curr. Opin. Otolaryngol. Head Neck Surg. 1998;6:395–400. doi: 10.1097/00020840-199812000-00008. - DOI
    1. Logemann J.A. Swallowing disorders. Best Pract. Res. Clin. Gastroenterol. 2007;21:563–573. doi: 10.1016/j.bpg.2007.03.006. - DOI - PubMed
    1. Giraldo-Cadavid L.F., Leal-Leaño L.R., Leon-Basantes G.A., Bastidas A.R., Garcia R., Ovalle S., Abondano-Garavito J.E. Accuracy of endoscopic and videofluoroscopic evaluations of swallowing for oropharyngeal dysphagia. Laryngoscope. 2017;127:2002–2010. doi: 10.1002/lary.26419. - DOI - PubMed
    1. Schindler A., Baijens L.W.J., Geneid A., Pizzorni N. Phoniatricians and otorhinolaryngologists approaching oropharyngeal dysphagia: An update on FEES. Eur. Arch. Otorhinolaryngol. 2022;279:2727–2742. doi: 10.1007/s00405-021-07161-1. - DOI - PMC - PubMed
    1. Pisegna J.M., Langmore S.E. Parameters of Instrumental Swallowing Evaluations: Describing a Diagnostic Dilemma. Dysphagia. 2016;31:462–472. doi: 10.1007/s00455-016-9700-3. - DOI - PubMed

LinkOut - more resources