Ideal entry point and trajectory for C2 pedicle screw placement in children: a 3D computed tomography study
- PMID: 36057908
- DOI: 10.1007/s00586-022-07374-w
Ideal entry point and trajectory for C2 pedicle screw placement in children: a 3D computed tomography study
Abstract
Purpose: To identify the ideal entry point for pediatric C2 pedicle screw and to obtain parameters of it for the indication of pediatric atlantoaxial fusion arthrodesis.
Methods: The pediatric cervical CT images were reconstructed into the 3D digital models and the C2 vertebrae were separated. The location of ideal entry point and screw placement related linear and angular parameters were assessed on the 3D digital models.
Results: A total of 214 pedicles from 107 C2 digital models were analyzed. The average entry point for C2 was 3.80 ± 2.78 mm medial to the lateral notch (LN) and 2.57 ± 1.70 mm superior to the LN. The average pedicle diameter (PD) was 6.02 ± 1.31 mm, and the average pedicle screw length (PSL) was 25.63 ± 3.46 mm. Statistical differences were found between different sex for PD and PSL (P < 0.05). As patient age increases, using the most lateral and inferior edge of the lateral mass as a reference marker, the entry point tends to move medial and cephalad, when using the LN as a reference marker, the entry point tends to move medial and slightly caudad. Univariate linear regression analysis suggested that these linear parameters were associated with age (P < 0.01).
Conclusion: In this study, we found that the measurement results of C2 pedicle screw varied based on sex, laterality, and ages for children younger than 18 years. The entry point of the screws facilitating ideal trajectory tends to change in a linear way as a function of age. This information helps the surgeon to establish the specific anatomy related to C2 pedicle screw placement to facilitate fixation in the pediatric patients.
Keywords: Cervical spine; Ideal entry point; Pediatric; Pedicle screw.
© 2022. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.
Similar articles
-
A New Entrance Technique for C2 Pedicle Screw Placement and the Use in Patients With Atlantoaxial Instability.Clin Spine Surg. 2017 Jun;30(5):E573-E577. doi: 10.1097/BSD.0000000000000164. Clin Spine Surg. 2017. PMID: 28525480 Clinical Trial.
-
Ideal entry point and trajectory for C2 pedicle screw placement in basilar invagination patients with high-riding vertebral artery based on 3D computed tomography.Spine J. 2022 Aug;22(8):1281-1291. doi: 10.1016/j.spinee.2022.04.015. Epub 2022 May 1. Spine J. 2022. PMID: 35508287
-
Ideal starting point and trajectory for C2 pedicle screw placement: a 3D computed tomography analysis using perioperative measurements.Spine J. 2014 Apr;14(4):615-8. doi: 10.1016/j.spinee.2013.06.077. Epub 2013 Nov 5. Spine J. 2014. PMID: 24200408
-
Anatomic considerations for the pedicle screw placement in the first cervical vertebra.Spine (Phila Pa 1976). 2005 Jul 1;30(13):1519-23. doi: 10.1097/01.brs.0000168546.17788.49. Spine (Phila Pa 1976). 2005. PMID: 15990666 Clinical Trial.
-
Accuracy and safety of C2 pedicle or pars screw placement: a systematic review and meta-analysis.J Orthop Surg Res. 2020 Jul 20;15(1):272. doi: 10.1186/s13018-020-01798-0. J Orthop Surg Res. 2020. PMID: 32690035 Free PMC article.
Cited by
-
Sagittal changes in the dens significantly slowed after 12 years of age.Brain Spine. 2025 Mar 11;5:104233. doi: 10.1016/j.bas.2025.104233. eCollection 2025. Brain Spine. 2025. PMID: 40144789 Free PMC article.
-
Influence of variations of craniovertebral junction anatomy on safe C1 lateral mass and C2 pedicle screw insertion: a cadaveric and radiologic study.Surg Radiol Anat. 2025 Apr 3;47(1):112. doi: 10.1007/s00276-025-03599-8. Surg Radiol Anat. 2025. PMID: 40178618
References
-
- Harms J, Melcher RP (2001) Posterior C1–C2 fusion with polyaxial screw and rod fixation. Spine (Phila Pa 1976) 26:2467–2471 - DOI
-
- Abumi K, Ito M, Sudo H (2012) Reconstruction of the subaxial cervical spine using pedicle screw instrumentation. Spine (Phila Pa 1976) 37:E349-356. https://doi.org/10.1097/BRS.0b013e318239cf1f - DOI
-
- Tukkapuram VR, Kuniyoshi A, Ito M (2019) A review of the historical evolution, biomechanical advantage, clinical applications, and safe insertion techniques of cervical pedicle screw fixation. Spine Surg Relat Res 3:126–135. https://doi.org/10.22603/ssrr.2018-0055 - DOI
-
- Huang DG, Hao DJ, He BR, Wu QN, Liu TJ, Wang XD, Guo H, Fang XY (2015) Posterior atlantoaxial fixation: a review of all techniques. Spine J Off J N Am Spine Soc 15:2271–2281. https://doi.org/10.1016/j.spinee.2015.07.008 - DOI
-
- Helenius I, Crawford H, Sponseller PD, Odent T, Bernstein RM, Stans AA, Hedequist D, Phillips JH (2015) Rigid fixation improves outcomes of spinal fusion for C1–C2 instability in children with skeletal dysplasias. J Bone Jt Surg Am 97:232–240. https://doi.org/10.2106/jbjs.n.00503 - DOI
MeSH terms
Supplementary concepts
Grants and funding
LinkOut - more resources
Full Text Sources
Research Materials
Miscellaneous