Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2022 Dec;31(12):3426-3432.
doi: 10.1007/s00586-022-07374-w. Epub 2022 Sep 4.

Ideal entry point and trajectory for C2 pedicle screw placement in children: a 3D computed tomography study

Affiliations

Ideal entry point and trajectory for C2 pedicle screw placement in children: a 3D computed tomography study

Sheng-Yu Fu et al. Eur Spine J. 2022 Dec.

Abstract

Purpose: To identify the ideal entry point for pediatric C2 pedicle screw and to obtain parameters of it for the indication of pediatric atlantoaxial fusion arthrodesis.

Methods: The pediatric cervical CT images were reconstructed into the 3D digital models and the C2 vertebrae were separated. The location of ideal entry point and screw placement related linear and angular parameters were assessed on the 3D digital models.

Results: A total of 214 pedicles from 107 C2 digital models were analyzed. The average entry point for C2 was 3.80 ± 2.78 mm medial to the lateral notch (LN) and 2.57 ± 1.70 mm superior to the LN. The average pedicle diameter (PD) was 6.02 ± 1.31 mm, and the average pedicle screw length (PSL) was 25.63 ± 3.46 mm. Statistical differences were found between different sex for PD and PSL (P < 0.05). As patient age increases, using the most lateral and inferior edge of the lateral mass as a reference marker, the entry point tends to move medial and cephalad, when using the LN as a reference marker, the entry point tends to move medial and slightly caudad. Univariate linear regression analysis suggested that these linear parameters were associated with age (P < 0.01).

Conclusion: In this study, we found that the measurement results of C2 pedicle screw varied based on sex, laterality, and ages for children younger than 18 years. The entry point of the screws facilitating ideal trajectory tends to change in a linear way as a function of age. This information helps the surgeon to establish the specific anatomy related to C2 pedicle screw placement to facilitate fixation in the pediatric patients.

Keywords: Cervical spine; Ideal entry point; Pediatric; Pedicle screw.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Harms J, Melcher RP (2001) Posterior C1–C2 fusion with polyaxial screw and rod fixation. Spine (Phila Pa 1976) 26:2467–2471 - DOI
    1. Abumi K, Ito M, Sudo H (2012) Reconstruction of the subaxial cervical spine using pedicle screw instrumentation. Spine (Phila Pa 1976) 37:E349-356. https://doi.org/10.1097/BRS.0b013e318239cf1f - DOI
    1. Tukkapuram VR, Kuniyoshi A, Ito M (2019) A review of the historical evolution, biomechanical advantage, clinical applications, and safe insertion techniques of cervical pedicle screw fixation. Spine Surg Relat Res 3:126–135. https://doi.org/10.22603/ssrr.2018-0055 - DOI
    1. Huang DG, Hao DJ, He BR, Wu QN, Liu TJ, Wang XD, Guo H, Fang XY (2015) Posterior atlantoaxial fixation: a review of all techniques. Spine J Off J N Am Spine Soc 15:2271–2281. https://doi.org/10.1016/j.spinee.2015.07.008 - DOI
    1. Helenius I, Crawford H, Sponseller PD, Odent T, Bernstein RM, Stans AA, Hedequist D, Phillips JH (2015) Rigid fixation improves outcomes of spinal fusion for C1–C2 instability in children with skeletal dysplasias. J Bone Jt Surg Am 97:232–240. https://doi.org/10.2106/jbjs.n.00503 - DOI

Supplementary concepts

Grants and funding

LinkOut - more resources