. 2022 Aug 31;19(17):10850.
doi: 10.3390/ijerph191710850.

Respiratory Symptoms and Skin Sick Building Syndrome among Office Workers at University Hospital, Chiang Mai, Thailand: Associations with Indoor Air Quality, AIRMED Project

Affiliations

Respiratory Symptoms and Skin Sick Building Syndrome among Office Workers at University Hospital, Chiang Mai, Thailand: Associations with Indoor Air Quality, AIRMED Project

Vithawat Surawattanasakul et al. Int J Environ Res Public Health. .

Abstract

Sick building syndrome (SBS) is the term used to describe the medical condition in which people in a building suffer from symptoms of illnesses for no apparent reason. SBS was found to be associated with indoor air quality (IAQ) but there are a variety of determinants (buildings, in particular). Identifying and controlling factors related to SBS is crucial for improving worker health and efficiency. A cross-sectional study was conducted to investigate (1) the prevalence of respiratory symptoms and skin SBS and (2) their associations with IAQ among office workers in administrative offices in an academic medical institute. A self-reporting questionnaire assessing the worker's characteristics, working conditions, and perception of working environments was used. The building assessment was via a walk-through survey and IAQ measurement. Of 290 office workers, 261 (90%) in 25 offices of 11 buildings took part in the survey. The highest prevalence of SBS was nasal symptoms (25.3%). We found that to reduce the risk of SBS, optimal air temperature levels in air-conditioned offices should be lower than 23 °C, with relative humidity between 60% and 70%. Lowering indoor CO2 levels below 700 ppm may be indicative of adequate ventilation to prevent SBS by reducing worker discomfort and indoor contaminants (e.g., formaldehyde).

Keywords: indoor air quality; office workers; sick building syndrome.

PubMed Disclaimer

Conflict of interest statement

The authors declare no conflict of interest.

Figures

Figure 1
Figure 1
The study flow diagram.
Figure 2
Figure 2
Prevalence of SBS symptoms.

References

    1. Dhungana P., Chalise M. Prevalence of sick building syndrome symptoms and its associated factors among bank employees in Pokhara Metropolitan, Nepal. Indoor Air. 2020;30:244–250. doi: 10.1111/ina.12635. - DOI - PubMed
    1. Lu C.Y., Tsai M.C., Muo C.H., Kuo Y.H., Sung F.C., Wu C.C. Personal, Psychosocial and Environmental Factors Related to Sick Building Syndrome in Official Employees of Taiwan. Int. J. Environ. Res. Public Health. 2017;15:7. doi: 10.3390/ijerph15010007. - DOI - PMC - PubMed
    1. Lu C.Y., Lin J.-M., Chen Y.-Y., Chen Y.-C. Building-Related Symptoms among Office Employees Associated with Indoor Carbon Dioxide and Total Volatile Organic Compounds. Int. J. Environ. Res. Public Health. 2015;12:5833–5845. doi: 10.3390/ijerph120605833. - DOI - PMC - PubMed
    1. Zamani M., Jalaludin J., Shaharon M.N. Indoor air quality and prevalence of sick building syndrome among office workers in two different offices in selangor. Am. J. Appl. Sci. 2013;10:1040–1047. doi: 10.3844/ajassp.2013.1140.1147. - DOI
    1. Apte M.G., Fisk W.J., Daisey J.M. Associations between indoor CO2 concentrations and sick building syndrome symptoms in U.S. office buildings: An analysis of the 1994–1996 BASE study data. Indoor Air. 2000;10:246–257. doi: 10.1034/j.1600-0668.2000.010004246.x. - DOI - PubMed

Publication types