Operator Variabilities in Carotid Pulse Wave Velocity Measured by an Image-free Ultrasound Device

Operator Variabilities in Carotid Pulse Wave Velocity Measured by an Image-free Ultrasound Device

Raj Kiran V et al. Annu Int Conf IEEE Eng Med Biol Soc. 2022 Jul.

Abstract

Local pulse wave velocity (PWV) has gained much attention in the last decade due to its ability to provide localized stiffness information from a target vessel and cater to several applications beyond regional PWV. Transit time-based methods are the most straightforward, but their reliability is highly dependent on the blood pulse sensing modality. Conventional ultrasound systems directly measure the blood pulse (as diameter or flow velocity); however, they offer limited frame rates resulting in poor resolution signals. Advanced systems supporting high frame rates are expensive, complex, and not amenable to field and resource-constraint settings. We have developed a high frame image-free ultrasound system to address this gap for automated and online measurement of local PWV. In an earlier in-vitro study, we have demonstrated its accuracy. In this work, we aim to investigate its in-vivo reliability. A study on 15 young, healthy subjects was conducted to assess the intra-and inter-operator repeatability of the developed system. The yielded local PWVs from the left carotid artery were within the range of 2.5 to 5.8 m/s. The device provided highly repeatable intra- and inter-operator measurements with ICC of 0.94 and 0.88, respectively. The bias for the intra- and inter-operator trials was statistically negligible (p > 0.005). The study demonstrated the potential of the high frame rate device to perform reliable measurements in-vivo. Clinical Relevance- This work aims to provide and validate an easy-to-use affordable and fully-automated high frame rate ultrasound technology for the measurement of online local PWV that is currently lacking.