Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 Apr;280(4):1629-1637.
doi: 10.1007/s00405-022-07633-y. Epub 2022 Sep 13.

Long-term outcomes of retrospective case series of middle ear implantation with Vibrant Soundbridge in children with congenital aural atresia

Affiliations

Long-term outcomes of retrospective case series of middle ear implantation with Vibrant Soundbridge in children with congenital aural atresia

Barbara Cadre et al. Eur Arch Otorhinolaryngol. 2023 Apr.

Abstract

Purpose: to assess audiological performance in quiet and noise, quality of life and side effects of Vibrant Soundbridge (VSB) in children with congenital aural atresia (CAA).

Methods: A retrospective study including consecutive patients with unilateral or bilateral CAA implanted with VSB from 2009 to 2020 in a tertiary referral centre.

Results: 18 patients with CAA and a present stapes were included (3 simultaneous bilateral VSB implants) and 21 ears: 17 VSB were attached to the short incus process, and four to the stapes. Age at implantation ranged from 4.7 to 15.8 years. Average follow-up was 6.5 years (± 3.7 years). In unilateral VSB, air conduction pure tone average (ACPTA) thresholds increased from 75.3 ± 15.2 to 32.6 ± 8.3 dB post-operatively (VSB activated) (n = 15; p < 0.01). The speech reception threshold (SRT) and the word recognition score (WRS) were significantly improved from 81.5 ± 10.4 to 43.9 ± 7.6 dB and 0% to 84.8 ± 8.5% postoperatively (n = 15; p < 0.01). The signal to noise ratio (SNR) was significantly improved from 2.1 ± 2.9 dB VSB inactivated to 0.3 ± 2.7 dB VSB activated (n = 15; p < 0.01). There was no significant difference in performance according to floating mass transducer (FMT) placement. 5/15 children were non-users at last follow-up in unilateral VSB and 0/3 in bilateral.

Conclusions: CAA ears with VSB activated had a significant improvement of ACPTA, WRS, SRT and SNR. A third of patients with unilateral CAA became non-users at last follow-up. The main challenge is to target the indications for the implantation of the VSB to avoid its discontinuation.

Keywords: Audiological assessment; Congenital aural atresia; Quality-of-life; Vibrant Soundbridge.

PubMed Disclaimer

References

    1. Abdel-Aziz M (2013) Congenital aural atresia. J Craniofac Surg 24:e418-422 - DOI - PubMed
    1. Luquetti DV, Heike CL, Hing AV et al (2012) Microtia: epidemiology and genetics. Am J Med Genet A 158A:124–139 - DOI - PubMed
    1. Leinung M, Zaretsky E, Lange BP et al (2017) Vibrant Soundbridge® in preschool children with unilateral aural atresia: acceptance and benefit. Eur Arch Otorhinolaryngol 274:159–165 - DOI - PubMed
    1. Kumpik DP, King AJ (2019) A review of the effects of unilateral hearing loss on spatial hearing. Hear Res 372:17–28 - DOI - PubMed - PMC
    1. Lloyd S, Almeyda J, Sirimanna KS et al (2007) Updated surgical experience with bone-anchored hearing aids in children. J Laryngol Otol 121:826–831 - DOI - PubMed

Supplementary concepts

LinkOut - more resources