Agreement between two photoplethysmography-based wearable devices for monitoring heart rate during different physical activity situations: a new analysis methodology
- PMID: 36104356
- PMCID: PMC9474518
- DOI: 10.1038/s41598-022-18356-9
Agreement between two photoplethysmography-based wearable devices for monitoring heart rate during different physical activity situations: a new analysis methodology
Abstract
Wearables are being increasingly used to monitor heart rate (HR). However, their usefulness for analyzing continuous HR in research or at clinical level is questionable. The aim of this study is to analyze the level of agreement between different wearables in the measurement of HR based on photoplethysmography, according to different body positions and physical activity levels, and compared to a gold-standard ECG. The proposed method measures agreement among several time scales since different wearables obtain HR at different sampling rates. Eighteen university students (10 men, 8 women; 22 ± 2.45 years old) participated in a laboratory study. Participants simultaneously wore an Apple Watch and a Polar Vantage watch. ECG was measured using a BIOPAC system. HR was recorded continuously and simultaneously by the three devices, for consecutive 5-min periods in 4 different situations: lying supine, sitting, standing and walking at 4 km/h on a treadmill. HR estimations were obtained with the maximum precision offered by the software of each device and compared by averaging in several time scales, since the wearables obtained HR at different sampling rates, although results are more detailed for 5 s and 30 s epochs. Bland-Altman (B-A) plots show that there is no noticeable difference between data from the ECG and any of the smartwatches while participants were lying down. In this position, the bias is low when averaging in both 5 s and 30 s. Differently, B-A plots show that there are differences when the situation involves some level of physical activity, especially for shorter epochs. That is, the discrepancy between devices and the ECG was greater when walking on the treadmill and during short time scales. The device showing the biggest discrepancy was the Polar Watch, and the one with the best results was the Apple Watch. We conclude that photoplethysmography-based wearable devices are suitable for monitoring HR averages at regular intervals, especially at rest, but their feasibility is debatable for a continuous analysis of HR for research or clinical purposes, especially when involving some level of physical activity. An important contribution of this work is a new methodology to synchronize and measure the agreement against a gold standard of two or more devices measuring HR at different and not necessarily even paces.
© 2022. The Author(s).
Conflict of interest statement
The authors declare no competing interests.
Figures





Similar articles
-
Accuracy of Consumer Wearable Heart Rate Measurement During an Ecologically Valid 24-Hour Period: Intraindividual Validation Study.JMIR Mhealth Uhealth. 2019 Mar 11;7(3):e10828. doi: 10.2196/10828. JMIR Mhealth Uhealth. 2019. PMID: 30855232 Free PMC article.
-
Pilot Study Assessing the Influence of Skin Type on the Heart Rate Measurements Obtained by Photoplethysmography with the Apple Watch.J Med Syst. 2019 May 22;43(7):195. doi: 10.1007/s10916-019-1325-2. J Med Syst. 2019. PMID: 31119387
-
Wrist-Worn and Arm-Worn Wearables for Monitoring Heart Rate During Sedentary and Light-to-Vigorous Physical Activities: Device Validation Study.JMIR Cardio. 2025 Mar 21;9:e67110. doi: 10.2196/67110. JMIR Cardio. 2025. PMID: 40116771 Free PMC article.
-
Can Wearable Devices Accurately Measure Heart Rate Variability? A Systematic Review.Folia Med (Plovdiv). 2018 Mar 1;60(1):7-20. doi: 10.2478/folmed-2018-0012. Folia Med (Plovdiv). 2018. PMID: 29668452
-
Validity of Wrist-Worn photoplethysmography devices to measure heart rate: A systematic review and meta-analysis.J Sports Sci. 2020 Sep;38(17):2021-2034. doi: 10.1080/02640414.2020.1767348. Epub 2020 Jun 19. J Sports Sci. 2020. PMID: 32552580
Cited by
-
Development and Calibration of a PATCH Device for Monitoring Children's Heart Rate and Acceleration.Med Sci Sports Exerc. 2024 Jun 1;56(6):1196-1207. doi: 10.1249/MSS.0000000000003404. Epub 2024 Feb 9. Med Sci Sports Exerc. 2024. PMID: 38377012 Free PMC article.
-
Validity and Reliability of Wearable Technology Devices during Simulated Pickleball Game Play.Sports (Basel). 2024 Aug 28;12(9):234. doi: 10.3390/sports12090234. Sports (Basel). 2024. PMID: 39330711 Free PMC article.
-
Accuracy of a Smartwatch to Assess Heart Rate Monitoring and Atrial Fibrillation in Stroke Patients.Sensors (Basel). 2023 May 10;23(10):4632. doi: 10.3390/s23104632. Sensors (Basel). 2023. PMID: 37430546 Free PMC article.
-
Assessment of Physiological Signals from Photoplethysmography Sensors Compared to an Electrocardiogram Sensor: A Validation Study in Daily Life.Sensors (Basel). 2024 Oct 24;24(21):6826. doi: 10.3390/s24216826. Sensors (Basel). 2024. PMID: 39517723 Free PMC article.
-
PhysioKit: An Open-Source, Low-Cost Physiological Computing Toolkit for Single- and Multi-User Studies.Sensors (Basel). 2023 Oct 4;23(19):8244. doi: 10.3390/s23198244. Sensors (Basel). 2023. PMID: 37837074 Free PMC article.
References
-
- Statista, Connected wearable devices worldwide 2016 to 2022. 2021.[Online]. http://www.statista.com/statistics/487291/global-connected-wearable-devi....
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources