Comparative Evaluation of Fracture Resistance of Endodontically Treated Bicuspids Instrumented With Hand Files, TruNatomy, ProTaper Next, ProTaper Gold, and WaveOne - An In vitro Study
- PMID: 36110709
- PMCID: PMC9469274
- DOI: 10.4103/jpbs.jpbs_739_21
Comparative Evaluation of Fracture Resistance of Endodontically Treated Bicuspids Instrumented With Hand Files, TruNatomy, ProTaper Next, ProTaper Gold, and WaveOne - An In vitro Study
Abstract
Aim: The study aims to compare and evaluate the fracture resistance of endodontically treated bicuspids instrumented with Hand Files, TruNatomy (TRN), ProTaper Next (PTN), ProTaper Gold (PTG), and WaveOne (WO).
Materials and methods: In total, 45 extracted single-rooted human premolar teeth were selected and sectioned at or below the cementoenamel junction to obtain roots 15 mm long. The samples were divided into four experimental groups and one control group (n = 9): instrumentation with nickel-titanium (NiTi) Hand Files (control group), instrumentation with TRN files, instrumentation with PTN files, instrumentation with PTG files, and instrumentation with WO files. The samples were obturated by lateral compaction technique using gutta-percha points and AH Plus sealer. A vertical load was applied to the tooth using the universal testing machine (Tecsol-TSI-BDS-2Kn-Sr No. 170710) for the fracture resistance test. Statistical analysis was performed.
Results: The study reported that teeth instrumented with NiTi hand files exhibited the highest fracture resistance when compared to all the rotary and reciprocating file systems. Among rotary and reciprocating instruments, root prepared with TRN files showed the most significant resistance to fracture compared with PTN, PTG, and WO files.
Conclusion: Within the limitations of this study, it can be concluded that minimally invasive instrumentation of the system preserves more pericervical dentin, which may increase the resistance to fracture. Results of this study and other studies support the use of minimally tapered instruments to improve the fracture resistance of endodontically treated teeth.
Keywords: Dentinal microcracks; NiTi Hand Files; ProTaper Gold; ProTaper Next rotary files; TruNatomy rotary files; WaveOne; fracture resistance; vertical root fracture.
Copyright: © 2022 Journal of Pharmacy and Bioallied Sciences.
Conflict of interest statement
There are no conflicts of interest.
Figures
References
-
- Bier CA, Shemesh H, Tanomaru-Filho M, Wesselink PR, Wu MK. The ability of different nickel-titanium rotary instruments to induce dentinal damage during canal preparation. J Endod. 2009;35:236–8. - PubMed
-
- Kim HC, Lee MH, Yum J, Versluis A, Lee CJ, Kim BM. Potential relationship between design of nickel-titanium rotary instruments and vertical root fracture. J Endod. 2010;36:1195–9. - PubMed
-
- Soros C, Zinelis S, Lambrianidis T, Palaghias G. Spreader load required for vertical root fracture during lateral compaction ex vivo: Evaluation of periodontal simulation and fracture load information. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2008;106:e64–70. - PubMed
-
- Lertchirakarn V, Palamara JE, Messer HH. Patterns of vertical root fracture: Factors affecting stress distribution in the root canal. J Endod. 2003;29:523–8. - PubMed
LinkOut - more resources
Full Text Sources
Research Materials