The electrochemical behavior of metallic implant materials as an indicator of their biocompatibility
- PMID: 3611146
- DOI: 10.1002/jbm.820210705
The electrochemical behavior of metallic implant materials as an indicator of their biocompatibility
Abstract
This study introduces a simple in vitro arrangement to measure current densities of implant metals. The in vivo condition of a metallic implant lying in tissues exhibiting different redox potentials is simulated in so-called straddle tests by applying a constant potential difference of 250 mV in saline containing the stable, fast-reacting redox system K4Fe(CN)6/K3Fe(CN)6. From a variety of corrosion-resistant implant metals and alloys, gold showed the highest current densities, followed by the stainless steel, the cobalt-based alloy, and the TiAIV-alloy. The pure metals titanium, niobium, and tantalum showed the lowest values. This can be explained by the stable oxide layer on these base metals, preventing an exchange of electrons and thus any redox reaction. This rating of metallic implant materials based on in vitro measurements of current densities is in good accordance with their biocompatibility rating reported from in vivo experiences. It seems that simple and cheap electrochemical tests allow an even more precise differentiation of the suitability of metallic materials for implant purposes than most of the conventional implantation tests, considering that biocompatibility is not only determined by corrosion products, but also by exchange currents and reaction products of redox processes involving tissue compounds.
Similar articles
-
Biomaterial optimization in total disc arthroplasty.Spine (Phila Pa 1976). 2003 Oct 15;28(20):S139-52. doi: 10.1097/01.BRS.0000092214.87225.80. Spine (Phila Pa 1976). 2003. PMID: 14560185
-
[Biodeterioration and corrosion of metallic implants and prostheses].Medicina (B Aires). 1993;53(3):260-74. Medicina (B Aires). 1993. PMID: 8114635 Review. Spanish.
-
Anodized titanium and stainless steel in contact with CFRP: an electrochemical approach considering galvanic corrosion.J Biomed Mater Res A. 2007 Sep 15;82(4):936-46. doi: 10.1002/jbm.a.31198. J Biomed Mater Res A. 2007. PMID: 17335021
-
[Biological evaluation of In-Ceram-ceramics compared to cobalt-base-alloys and the metals titanium, tantalum and niobium in animal experiments].Dtsch Stomatol (1990). 1991;41(11):407-10. Dtsch Stomatol (1990). 1991. PMID: 1817651 German.
-
Metallic implants used in foot surgery.Clin Podiatr Med Surg. 1995 Jul;12(3):457-74. Clin Podiatr Med Surg. 1995. PMID: 7553535 Review.
Cited by
-
A promising biodegradable magnesium alloy suitable for clinical vascular stent application.Sci Rep. 2017 Apr 11;7:46343. doi: 10.1038/srep46343. Sci Rep. 2017. PMID: 28397881 Free PMC article.
-
Phase-Dependent Photocatalytic Activity of Nb2O5 Nanomaterials for Rhodamine B Degradation: The Role of Surface Chemistry and Crystal Structure.Nanomaterials (Basel). 2025 Jun 1;15(11):846. doi: 10.3390/nano15110846. Nanomaterials (Basel). 2025. PMID: 40497894 Free PMC article.
-
3Y-TZP/Ta Biocermet as a Dental Material: An Analysis of the In Vitro Adherence of Streptococcus Oralis Biofilm and an In Vivo Pilot Study in Dogs.Antibiotics (Basel). 2024 Feb 9;13(2):175. doi: 10.3390/antibiotics13020175. Antibiotics (Basel). 2024. PMID: 38391561 Free PMC article.
-
First in-human randomized comparison of an anodized niobium stent versus a standard stainless steel stent--an intravascular ultrasound and angiographic two-center study: the VELA study.Clin Res Cardiol. 2006 Sep;95(9):455-60. doi: 10.1007/s00392-006-0406-7. Epub 2006 Jul 3. Clin Res Cardiol. 2006. PMID: 16799877 Clinical Trial.
-
Photoinduced properties of anodized Ti alloys for biomaterial applications.Sci Rep. 2023 Aug 25;13(1):13916. doi: 10.1038/s41598-023-41189-z. Sci Rep. 2023. PMID: 37626098 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources