Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2022:2546:35-43.
doi: 10.1007/978-1-0716-2565-1_4.

Quantification of Plasma S-adenosylmethionine and S-adenosylhomocysteine Using Liquid Chromatography-Electrospray-Tandem Mass Spectrometry

Affiliations

Quantification of Plasma S-adenosylmethionine and S-adenosylhomocysteine Using Liquid Chromatography-Electrospray-Tandem Mass Spectrometry

Erland Arning et al. Methods Mol Biol. 2022.

Abstract

We describe a simple stable isotope dilution method for accurate determination of S-adenosylmethionine (SAM) and S-adenosylhomocysteine (SAH) in plasma as a clinical diagnostic test. Determination of SAM/SAH in plasma (20 μL) was performed by high-performance liquid chromatography coupled with electrospray positive ionization tandem mass spectrometry (HPLC-ESI-MS/MS). Calibrators (SAM and SAH) and internal standards (2H3-SAM and 2H4-SAH) were included in each analytical run for calibration. Sample preparation involved combining 20 μL sample with 180 μL of internal standard solution consisting of heavy-isotope-labeled internal standards in mobile phase A and filtering by ultracentrifugation through a 10 kd MW cutoff membrane. Sample filtrate (3 μL) was injected by a Shimadzu Nexera LC System interfaced with a 5500 QTRAP® (Sciex). Chromatographic separation was achieved on a 250 mm × 2.0 mm EZ-faast column from Phenomenex. Samples were eluted at a flow rate of 0.20 mL/min with a binary gradient with a total run time of 10 min. The source operated in positive ion mode at an ion spray voltage of +5000 V. SAM and SAH resolved by a gradient to 100% methanol with retention times of 5.8 and 5.5 min, respectively. HPLC chromatographic conditions did not produce complete separation of SAM and SAH, but they were completely discerned by their different fragmentation pattern in the mass spectrometer working in the MS-MS mode. The observed m/z values of the fragment ions were m/z 399→250 for SAM, m/z 385→136 for SAH, m/z 402→250 for 2H3-SAM, and m/z 203→46. The calibration curve was linear over the range of 12.5-5000 nmol/L for SAM and SAH.

Keywords: Mass spectrometry; Methylation; S-adenosylhomocysteine; S-adenosylmethionine.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Kim YI (2005) Nutritional epigenetics: impact of folate deficiency on DNA methylation and colon cancer susceptibility. J Nutr 135:2703–2709 - DOI - PubMed
    1. Hoffman DR, Cornatzer WE, Duerre JA (1979) Relationship between tissue levels of S-adenosylmethionine, S-adenosylhomocysteine and transmethylation reactions. Can J Biochem 57:56–65 - DOI - PubMed
    1. Yi P, Melnyk S, Pogribna M, Pogribny IP, Hine RJ, James SJ (2000) Parallel increases in plasma S-adenosylhomocysteine and lymphocyte DNA hypomethylation. J Biol Chem 275(38):239318–239323 - DOI
    1. Cantoni GL (1985) The role of S-adenosylhomocysteine in the biological utilization of S-adenosylmethionine. Prog Clin Biol Res 198:47–65 - PubMed
    1. Mudd SH (2011) Hypermethioninemias of genetic and non-genetic origin: a review. Am J Med Genet C Semin Med Genet 157C(1):3–32 - DOI - PubMed

LinkOut - more resources