Impact of self-tonometry on glaucoma treatment decision
- PMID: 36147012
- DOI: 10.1111/aos.15256
Impact of self-tonometry on glaucoma treatment decision
Abstract
Purpose: The aim of this study was to examine the impact of self-tonometry on clinicians' decision in glaucoma treatment.
Materials and methods: Medical records of 133 patients who had performed self-tonometry using iCare® Home between January and December 2019 were retrospectively reviewed. Inclusion criteria were as follows: age over 18 years, all types of glaucoma, as well as ocular hypertension and glaucoma suspect, compliance with tonometer manufacturer's recommendations and monitoring over at least 2 days. The data consisted of age, gender, diagnosis, visual field index, rate of progression and type of treatment pre- and post-intraocular pressure (IOP) phasing. The following IOP measurements were used to calculate the mean and maximum IOP, and range over each day and consecutive days: Goldmann applanation tonometry (GAT) measurements from referral and training visits and iCare® Home measurements made by the trainers and the patients themselves. A total of 90 patients were included.
Results: Clinicians were satisfied with the actual treatment in 54.4% of the cases. There was a statistically significant difference between the clinicians' decision to maintain same treatment or to escalate therapy for all the mean and maximum IOPs measured on each single day and over a 2- or 3-day period (p < 0.002).
Conclusion: Our results suggest that the presence of high IOP values obtained with self-tonometry supports an intensification of glaucoma treatment. Self-tonometry provides clinicians with an important complement for clinical decision-making, and under- or over-treatment may be avoided for the benefit of patients.
Keywords: Goldmann applanation tonometry; glaucoma treatment; iCare® Home; intraocular pressure; self-tonometry.
© 2022 The Authors. Acta Ophthalmologica published by John Wiley & Sons Ltd on behalf of Acta Ophthalmologica Scandinavica Foundation.
References
REFERENCES
-
- Asrani, S., Zeimer, R., Wilensky, J., Gieser, D., Vitale, S. & Lindenmuth, K. (2000) Large diurnal fluctuations in intraocular pressure are an independent risk factor in patients with glaucoma. Journal of Glaucoma, 9, 134-142.
-
- Barkana, Y., Anis, S., Liebmann, J., Tello, C. & Ritch, R. (2006) Clinical utility of intraocular pressure monitoring outside of normal office hours in patients with glaucoma. Archives of Ophthalmology, 124(6), 793-797.
-
- Bengtsson, B. & Heijl, A. (2005) Diurnal IOP fluctuation: not an independent risk factor for glaucomatous visual field loss in high-risk ocular hypertension. Graefe's Archive for Clinical and Experimental Ophthalmology, 243(6), 513-518.
-
- Chauhan, B.C., Mikelberg, F.S., Balaszi, A.G., LeBlanc, R.P., Lesk, M.R. & Trope, G.E. (2008) Canadian glaucoma study: 2. Risk factors for the progression of open-angle glaucoma. Archives of Ophthalmology, 126(8), 1030-1036.
-
- Chen, E., Querat, L. & Akerstedt, C. (2016) Self-tonometry as a complement in the investigation of glaucoma patients. Acta Ophthalmologica, 94(8), 788-792.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical