Randomized Controlled Trial
. 2023 Jan 13;76(2):238-244.
doi: 10.1093/cid/ciac789.

Bronchial Washing Using a Thin Versus a Thick Bronchoscope to Diagnose Pulmonary Tuberculosis: A Randomized Trial

Affiliations
Randomized Controlled Trial

Bronchial Washing Using a Thin Versus a Thick Bronchoscope to Diagnose Pulmonary Tuberculosis: A Randomized Trial

Jung Seop Eom et al. Clin Infect Dis. .

Abstract

Background: This study was performed to evaluate the efficacy of using a thin bronchoscope for the diagnosis of pulmonary tuberculosis (PTB).

Methods: Between March 2019 and November 2021, we prospectively enrolled participants with suspected PTB whose sputum acid-fast bacilli (AFB) smear and tuberculosis (TB) polymerase chain reaction (PCR) tests were negative or who could not produce self-expectorated sputum. Participants were randomized to a control group (bronchial washing [BW] using a 5.9-mm conventional bronchoscope guided by chest computed tomography) or an investigational group (BW using a 4.0-mm thin bronchoscope under virtual bronchoscopic navigation guidance). The primary outcome was detection of TB in BW fluid, defined as a positive result in the Xpert MTB/RIF assay. The secondary outcomes included AFB smear and Mycobacterium tuberculosis culture positivity, time to treatment initiation, and bronchoscopy-related complications.

Results: In total, 85 participants were included in the final analysis (43 in the control group and 42 in the investigational group). Twenty-three and 29, respectively, were finally diagnosed with PTB. The TB detection rate in BW fluid was higher in the investigational group (72.4% vs 43.5%, P = .035). Mycobacterium tuberculosis culture positivity was also higher in the investigational group (79.3% vs 52.2%, P = .038). No participants required premature bronchoscopy termination because of complications. Of the participants with PTB, the time to treatment initiation was shorter in the investigational group (median, 2.0 days vs 4.0 days, P = .001).

Conclusions: BW using a thin bronchoscope increases the TB detection rate in patients with PTB compared to conventional bronchoscopy. Clinical Trials Registration.ȃNCT03802812.

Keywords: bronchoscopy; thin; tuberculosis.

PubMed Disclaimer

Publication types

Associated data