Variability of the VA interval at tachycardia induction: a simple method to differentiate orthodromic reciprocating tachycardia from atypical atrioventricular nodal reentrant tachycardia
- PMID: 36152135
- DOI: 10.1007/s10840-022-01376-w
Variability of the VA interval at tachycardia induction: a simple method to differentiate orthodromic reciprocating tachycardia from atypical atrioventricular nodal reentrant tachycardia
Abstract
Background: The differential diagnosis between orthodromic atrioventricular reentry tachycardia (AVRT) and atypical AV nodal reentrant tachycardia (aAVNRT) is sometimes challenging. We hypothesize that aAVNRTs have more variability in the retrograde conduction time at tachycardia onset than AVRTs.
Methods: We aimed to assess the variability in retrograde conduction time at tachycardia onset in AVRT and aAVNRT and to propose a new diagnostic tool to differentiate these two arrhythmia mechanisms. We measured the VA interval of the first beats after tachycardia induction until it stabilized. The difference between the maximum and minimum VA intervals (∆VA) and the number of beats needed for the VA interval to stabilize was analyzed. Atrial tachycardias were excluded.
Results: A total of 107 patients with aAVNRT (n = 37) or AVRT (n = 64) were included. Six additional patients with decremental accessory pathway-mediated tachycardia (DAPT) were analyzed separately. All aAVNRTs had VA interval variability. The median ∆VA was 0 (0 - 5) ms in AVRTs vs 40 (21 - 55) ms in aAVNRTs (p < 0.001). The VA interval stabilized significantly earlier in AVRTs (median 1.5 [1 - 3] beats) than in aAVNRTs (5 [4 - 7] beats; p < 0.001). A ∆VA < 10 ms accurately differentiated AVRT from aAVNRT with 100% of sensitivity, specificity, and positive and negative predictive values. The stabilization of the VA interval at < 3 beats of the tachycardia onset identified AVRT with sensitivity, specificity, and positive and negative predictive values of 64.1%, 94.6%, 95.3%, and 60.3%, respectively. A ∆VA < 20 ms yielded good diagnostic accuracy for DAPT.
Conclusions: A ∆VA < 10 ms is a simple and useful criterion that accurately distinguished AVRT from atypical AVNRT. Central panel: Scatter plot showing individual values of ∆VA in atypical AVNRT and AVRT. Left panel: induction of atypical AVNRT. The VA interval stabilizes at the 5th beat and the ∆VA is 62 ms (maximum VA interval: 172 ms - minimum VA interval: 110 ms). Right panel: induction of AVRT. The tachycardia has a fixed VA interval from the first beat. ∆VA is 0 ms.
Keywords: Atypical AV nodal reentry tachycardia; Decremental accessory pathway; Orthodromic AV reentry tachycardia; Supraventricular tachycardia; VA interval.
© 2022. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.
References
-
- Kadish AH, Morady F. The response of paroxysmal supraventricular tachycardia to overdrive atrial and ventricular pacing: can it help determine the tachycardia mechanism? J Cardiovasc Electrophysiol. 1993;4:239–52. - PubMed
-
- Ormaetxe JM, Almendral J, Arenal A, et al. Ventricular fusion during resetting and entrainment of orthodromic supraventricular tachycardia involving septal accessory pathways. Implications for the differential diagnosis with atrioventricular nodal reentry. Circulation. 1993;88:2623–31. - PubMed
-
- Martínez-Alday JD, Almendral J, Arenal A, et al. Identification of concealed posteroseptal Kent pathways by comparison of ventriculoatrial intervals from apical and posterobasal right ventricular sites. Circulation. 1994;89:1060–7. - PubMed
-
- Hirao K, Otomo K, Wang X, et al. Para-Hisian pacing. A new method for differentiating retrograde conduction over an accessory AV pathway from conduction over the AV node. Circulation. 1996;94:1027–35. - PubMed
-
- Knight BP, Ebinger M, Oral H, et al. Diagnostic value of tachycardia features and pacing maneuvers during paroxysmal supraventricular tachycardia. J Am Coll Cardiol. 2000;36:574–82. - PubMed
MeSH terms
LinkOut - more resources
Full Text Sources