Streaking artifact reduction for CBCT-based synthetic CT generation in adaptive radiotherapy
- PMID: 36183234
- DOI: 10.1002/mp.16017
Streaking artifact reduction for CBCT-based synthetic CT generation in adaptive radiotherapy
Abstract
Background: Cone-beam computed tomography (CBCT) is widely used for daily image guidance in radiation therapy, enhancing the reproducibility of patient setup. However, its application in adaptive radiotherapy (ART) is limited by many imaging artifacts and inaccurate Hounsfield units (HUs). The correction of CBCT image is necessary and of great value for CBCT-based ART.
Purpose: To explore the synthetic CT (sCT) generation from CBCT images of thorax and abdomen patients, which usually surfer from serious artifacts duo to organ state changes. In this study, a streaking artifact reduction network (SARN) is proposed to reduce artifacts and combine with cycleGAN to generate high-quality sCT images from CBCT and achieve an accurate dose calculation.
Methods: The proposed SARN was trained in a self-supervised manner. Artifact-CT images were generated from planning CT by random deformation and projection replacement, and SARN was trained based on paired artifact-CT and CT images. The planning CT and CBCT images of 260 patients with cancer, including 120 thoracic and 140 abdominal CT scans, were used to train and evaluate neural networks. The CBCT images of another 12 patients in late treatment fractions, which contained large anatomy changes, were also tested by trained models. The trained models include commonly used U-Net, cycleGAN, attention-gated cycleGAN (cycAT), and cascade models combined SARN with cycleGAN or cycAT. The generated sCT images were compared in terms of image quality and dose calculation accuracy.
Results: The sCT images generated by SARN combined with cycleGAN and cycAT showed the best image quality, removed the most artifacts, and retained the normal anatomical structure. The SARN+cycleGAN performed best in streaking artifacts removal with the maximum percent integrity uniformity (PIUm ) of 91.0% and minimum standard deviation (SD) of 35.4 HU for delineated artifact regions among all models. The mean absolute error (MAE) of CBCT images in the thorax and abdomen were 71.6 and 55.2 HU, respectively, using planning CT images after deformable registration as ground truth. Compared with CBCT, the thoracic and abdominal sCT images generated by each model had significantly improved image quality with smaller MAE (p < 0.05). The SARN+cycAT obtained the minimum MAEs of 42.5 HU in the thorax while SARN+cycleGAN got the minimum MAEs of 32.0 HU in the abdomen. The sCT generated by U-Net had a remarkably lower anatomical structure accuracy compared with the other models. The thoracic and abdominal sCT images generated by SARN+cycleGAN showed optimal dose calculation accuracy with gamma passing rates (2 mm/2%) of 98.2% and 96.9%, respectively.
Conclusions: The proposed SARN can reduce serious streaking artifacts in CBCT images. The SARN combined with cycleGAN can generate high-quality sCT images with fewer artifacts, high-accuracy HU values, and accurate anatomical structures, thus providing reliable dose calculation in ART.
Keywords: CBCT; adaptive radiotherapy; image quality; streaking artifacts; synthetic CT.
© 2022 American Association of Physicists in Medicine.
Similar articles
-
Generating synthetic CT from low-dose cone-beam CT by using generative adversarial networks for adaptive radiotherapy.Radiat Oncol. 2021 Oct 14;16(1):202. doi: 10.1186/s13014-021-01928-w. Radiat Oncol. 2021. PMID: 34649572 Free PMC article.
-
Generating synthesized computed tomography (CT) from cone-beam computed tomography (CBCT) using CycleGAN for adaptive radiation therapy.Phys Med Biol. 2019 Jun 10;64(12):125002. doi: 10.1088/1361-6560/ab22f9. Phys Med Biol. 2019. PMID: 31108465
-
CBCT-based synthetic CT generated using CycleGAN with HU correction for adaptive radiotherapy of nasopharyngeal carcinoma.Sci Rep. 2023 Apr 24;13(1):6624. doi: 10.1038/s41598-023-33472-w. Sci Rep. 2023. PMID: 37095147 Free PMC article.
-
[Advances in low-dose cone-beam computed tomography image reconstruction methods based on deep learning].Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2025 Jun 25;42(3):635-642. doi: 10.7507/1001-5515.202409021. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2025. PMID: 40566788 Free PMC article. Review. Chinese.
-
The application of metal artifact reduction methods on computed tomography scans for radiotherapy applications: A literature review.J Appl Clin Med Phys. 2021 Jun;22(6):198-223. doi: 10.1002/acm2.13255. Epub 2021 May 3. J Appl Clin Med Phys. 2021. PMID: 33938608 Free PMC article.
Cited by
-
CBCT-to-CT synthesis using a hybrid U-Net diffusion model based on transformers and information bottleneck theory.Sci Rep. 2025 Mar 28;15(1):10816. doi: 10.1038/s41598-025-92094-6. Sci Rep. 2025. PMID: 40155469 Free PMC article.
-
Using RegGAN to generate synthetic CT images from CBCT images acquired with different linear accelerators.BMC Cancer. 2023 Sep 5;23(1):828. doi: 10.1186/s12885-023-11274-7. BMC Cancer. 2023. PMID: 37670252 Free PMC article.
-
Unsupervised Bayesian generation of synthetic CT from CBCT using patient-specific score-based prior.Med Phys. 2025 Apr;52(4):2238-2246. doi: 10.1002/mp.17572. Epub 2024 Dec 12. Med Phys. 2025. PMID: 39666566 Free PMC article.
-
CBCT-Based synthetic CT image generation using conditional denoising diffusion probabilistic model.Med Phys. 2024 Mar;51(3):1847-1859. doi: 10.1002/mp.16704. Epub 2023 Aug 30. Med Phys. 2024. PMID: 37646491 Free PMC article.
-
Generating missing patient anatomy from partially acquired cone-beam computed tomography images using deep learning: a proof of concept.Phys Eng Sci Med. 2023 Sep;46(3):1321-1330. doi: 10.1007/s13246-023-01302-y. Epub 2023 Jul 18. Phys Eng Sci Med. 2023. PMID: 37462889 Free PMC article.
References
REFERENCES
-
- Barker JL Jr, Garden AS, Ang KK, et al. Quantification of volumetric and geometric changes occurring during fractionated radiotherapy for head-and-neck cancer using an integrated CT/linear accelerator system. Int J Radiat Oncol Biol Phys. 2004;59(4):960-970.
-
- Yan D, Vicini F, Wong J, Martinez A. Adaptive radiation therapy. Phys Med Biol. 1997;42(1):123-132.
-
- Sonke JJ, Aznar M, Rasch C. Adaptive radiotherapy for anatomical changes. Semin Radiat Oncol. 2019;29(3):245-257.
-
- Cho PS, Johnson RH, Griffin TW. Cone-beam CT for radiotherapy applications. Phys Med Biol. 1995;40:1863-1883.
-
- Lai CJ, Chen L, Zhang H, et al. Reduction in x-ray scatter and radiation dose for volume-of-interest (VOI) cone-beam breast CT-a phantom study. Phys Med Biol. 2009;54(21):6691-6709.
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources