Two-piece zirconia implants in the posterior mandible and maxilla: A cohort study with a follow-up period of 9 years
- PMID: 36184914
- DOI: 10.1111/clr.14005
Two-piece zirconia implants in the posterior mandible and maxilla: A cohort study with a follow-up period of 9 years
Abstract
Objectives: Long-term follow-up observations of zirconia implants are rare. This study aimed at evaluating the clinical performance of two-piece zirconia implants in the posterior jaws over 9 years.
Materials and methods: Sixty partially edentulous patients were treated with two-piece zirconia implants. In eight no primary stability could be achieved. Fifty-two patients received the final restoration (i.e., cemented fibreglass abutments and all-ceramic crowns). After 2 years, 2 implants failed and 4 dropouts were recorded. The remaining 46 patients with one target implant each were recalled at 9 years. Besides implant survival, clinical parameters at the implant level (plaque index-PI, bleeding on probing-BOP, probing depth-PD, mucosal recession-MR) were recorded and compared with previously collected data. Mechanical and technical complications were assessed.
Results: Thirty patients responded. The mean observation period was of 111.1 ± 2.2 months. One implant was lost. Data recorded from the remaining 29 implants were analysed. PI values increased overtime. Mean BOP and PD remained unchanged during follow-up. No additional cases of peri-implantitis were recorded over the 10 diagnosed during the first 2 years of follow-up. No significant changes in mean MR values were detected over time, with 65% of the all included implants exhibiting no recession at 9 years and all the others, but one, a maximum MR of 1 mm. Three technical and 6 mechanical complications occurred in 7 patients between 2- and 9-years (6.9% and 20.7%, respectively, at patient level).
Conclusion: Within the limitations of the present study, a high survival rate was registered. Albeit frequent mechanical and technical complications, two-piece zirconia implants could represent a valid solution for the replacement of single teeth in the posterior jaws.
Keywords: clinical study; implant survival; zirconia implants.
© 2022 The Authors. Clinical Oral Implants Research published by John Wiley & Sons Ltd.
References
REFERENCES
-
- Al-Radha, A. S., Dymock, D., Younes, C., & O'Sullivan, D. (2012). Surface properties of titanium and zirconia dental implant materials and their effect on bacterial adhesion. Journal of Dentistry, 40(2), 146-153. https://doi.org/10.1016/j.jdent.2011.12.006
-
- Becker, J., John, G., Becker, K., Mainusch, S., Diedrichs, G., & Schwarz, F. (2017). Clinical performance of two-piece zirconia implants in the posterior mandible and maxilla: A prospective cohort study over 2 years. Clinical Oral Implants Research, 28(1), 29-35. https://doi.org/10.1111/clr.12610
-
- Berglundh, J., Romandini, M., Derks, J., Sanz, M., & Berglundh, T. (2021). Clinical findings and history of bone loss at implant sites. Clinical Oral Implants Research, 32(3), 314-323. https://doi.org/10.1111/clr.13701
-
- Berglundh, T., Armitage, G., Araujo, M. G., Avila-Ortiz, G., Blanco, J., Camargo, P. M., Chen, S., Cochran, D., Derks, J., Figuero, E., Hämmerle, C. H. F., Heitz-Mayfield, L. J. A., Huynh-Ba, G., Iacono, V., Koo, K. T., Lambert, F., McCauley, L., Quirynen, M., Renvert, S., … Zitzmann, N. (2018). Peri-implant diseases and conditions: Consensus report of workgroup 4 of the 2017 world workshop on the classification of periodontal and peri-implant diseases and conditions. Journal of Clinical Periodontology, 45(Suppl. 20), S286-S291. https://doi.org/10.1111/jcpe.12957
-
- Bressan, E., Paniz, G., Lops, D., Corazza, B., Romeo, E., & Favero, G. (2011). Influence of abutment material on the gingival color of implant-supported all-ceramic restorations: A prospective multicenter study. Clinical Oral Implants Research, 22(6), 631-637. https://doi.org/10.1111/j.1600-0501.2010.02008.x