. 1987 Sep;77(9):1195-7.
doi: 10.2105/ajph.77.9.1195.

Prevention of tap water scald burns: evaluation of a multi-media injury control program

Prevention of tap water scald burns: evaluation of a multi-media injury control program

M L Katcher. Am J Public Health. 1987 Sep.

Abstract

A prospective study was designed to evaluate a mass media injury prevention program reaching two million people to determine its impact on risk awareness of hot tap water burns and injury-prevention behavior. Liquid-crystal thermometers for testing hot water temperature were offered at no cost; 140,000 were requested. Pre- and post-program general population random surveys (N = 337 and 318, respectively) found increased awareness of the danger of hot tap water, from 72 per cent to 89 per cent, but no increase in testing or lowering of water heater temperatures. A third random sample survey (N = 325) among thermometer requesters found a higher rate of testing (difference 58.1 per cent, 95 per cent CL 55.3 per cent, 60.9 per cent) than in the general population. Of those who tested, 43 per cent reported temperatures in the dangerous range of 54.4 degrees C (130 degrees F) or greater; 52 per cent of this group lowered their water heater thermostat. These findings indicate that: more than 25 per cent of the public is unaware of the potential danger of hot tap water; a safety education program which increases awareness will not necessarily result in injury-control behavior; and most people motivated to request a free thermometer will test their hot water temperature and lower it if necessary. As a result of this effort, thermostats of an estimated 20,000 water heaters were lowered from dangerously high levels.

PubMed Disclaimer

References

    1. JAMA. 1981 Sep 11;246(11):1219-22 - PubMed
    1. Pediatrics. 1985 Jan;75(1):14-8 - PubMed
    1. Pediatrics. 1978 Sep;62(3):280-7 - PubMed
    1. Pediatrics. 1978 Jul;62(1):1-7 - PubMed
    1. Wis Med J. 1982 Feb;81(2):25-8 - PubMed

Publication types

LinkOut - more resources