Development and validation of a new ICD-10-based screening colonoscopy overuse measure in a large integrated healthcare system: a retrospective observational study
- PMID: 36192148
- PMCID: PMC10294020
- DOI: 10.1136/bmjqs-2021-014236
Development and validation of a new ICD-10-based screening colonoscopy overuse measure in a large integrated healthcare system: a retrospective observational study
Abstract
Background: Low-value use of screening colonoscopy is wasteful and potentially harmful to patients. Decreasing low-value colonoscopy prevents procedural complications, saves patient time and reduces patient discomfort, and can improve access by reducing procedural demand. The objective of this study was to develop and validate an electronic measure of screening colonoscopy overuse using International Classification of Diseases, Tenth Edition codes and then apply this measure to estimate facility-level overuse to target quality improvement initiatives to reduce overuse in a large integrated healthcare system.
Methods: Retrospective national observational study of US Veterans undergoing screening colonoscopy at 119 Veterans Health Administration (VHA) endoscopy facilities in 2017. A measure of screening colonoscopy overuse was specified by an expert workgroup, and electronic approximation of the measure numerator and denominator was performed ('electronic measure'). The electronic measure was then validated via manual record review (n=511). Reliability statistics (n=100) were calculated along with diagnostic test characteristics of the electronic measure. The measure was then applied to estimate overall rates of overuse and facility-level variation in overuse among all eligible patients.
Results: The electronic measure had high specificity (99%) and moderate sensitivity (46%). Adjusted positive predictive value and negative predictive value were 33% and 95%, respectively. Inter-rater reliability testing revealed near perfect agreement between raters (k=0.81). 269 572 colonoscopies were performed in VHA in 2017 (88 143 classified as screening procedures). Applying the measure to these 88 143 screening colonoscopies, 24.5% were identified as potential overuse. Median facility-level overuse was 22.5%, with substantial variability across facilities (IQR 19.1%-27.0%).
Conclusions: An International Classification of Diseases, Tenth Edition based electronic measure of screening colonoscopy overuse has high specificity and improved sensitivity compared with a previous International Classification of Diseases, Ninth Edition based measure. Despite increased focus on reducing low-value care and improving access, a quarter of VHA screening colonoscopies in 2017 were identified as potential low-value procedures, with substantial facility-level variability.
Keywords: General practice; Healthcare quality improvement; Performance measures.
© Author(s) (or their employer(s)) 2023. No commercial re-use. See rights and permissions. Published by BMJ.
Conflict of interest statement
Competing interests: None declared.
Figures

Comment in
-
How can routine colorectal cancer screening in the USA be considered low value in other countries?BMJ Qual Saf. 2023 Jul;32(7):379-382. doi: 10.1136/bmjqs-2022-015576. Epub 2023 Mar 13. BMJ Qual Saf. 2023. PMID: 36914279 No abstract available.
Similar articles
-
Determinants of referral network size for screening colonoscopies in the Veterans Health Administration after the implementation of the MISSION Act.Health Serv Res. 2024 Feb;59(1):e14239. doi: 10.1111/1475-6773.14239. Epub 2023 Sep 26. Health Serv Res. 2024. PMID: 37750017 Free PMC article.
-
Developing and Testing an Electronic Measure of Screening Colonoscopy Overuse in a Large Integrated Healthcare System.J Gen Intern Med. 2016 Apr;31 Suppl 1(Suppl 1):53-60. doi: 10.1007/s11606-015-3569-y. J Gen Intern Med. 2016. PMID: 26951277 Free PMC article.
-
Impacts of COVID-19 on Appropriate Use of Screening Colonoscopy in a Large Integrated Healthcare Delivery System.J Gen Intern Med. 2023 Aug;38(11):2577-2583. doi: 10.1007/s11606-023-08233-0. Epub 2023 May 25. J Gen Intern Med. 2023. PMID: 37231209 Free PMC article.
-
An Estimate of the US Rate of Overuse of Screening Colonoscopy: a Systematic Review.J Gen Intern Med. 2022 May;37(7):1754-1762. doi: 10.1007/s11606-021-07263-w. Epub 2022 Feb 25. J Gen Intern Med. 2022. PMID: 35212879 Free PMC article.
-
Options for screening colonoscopy without sedation: a pilot study in United States veterans.Aliment Pharmacol Ther. 2007 Aug 15;26(4):627-31. doi: 10.1111/j.1365-2036.2007.03404.x. Aliment Pharmacol Ther. 2007. PMID: 17661766 Review.
Cited by
-
Determinants of referral network size for screening colonoscopies in the Veterans Health Administration after the implementation of the MISSION Act.Health Serv Res. 2024 Feb;59(1):e14239. doi: 10.1111/1475-6773.14239. Epub 2023 Sep 26. Health Serv Res. 2024. PMID: 37750017 Free PMC article.
-
CLINICAL DIAGNOSIS CODES IDENTIFY PATIENTS UNLIKELY TO RECEIVE ORDERS FOR FECAL IMMUNOCHEMICAL TESTS.medRxiv [Preprint]. 2025 Jun 9:2025.06.07.25327375. doi: 10.1101/2025.06.07.25327375. medRxiv. 2025. PMID: 40585097 Free PMC article. Preprint.
-
Healthcare utilization, mortality, and cardiovascular events following GLP1-RA initiation in chronic kidney disease.Nat Commun. 2024 Dec 5;15(1):10623. doi: 10.1038/s41467-024-54009-3. Nat Commun. 2024. PMID: 39639039 Free PMC article.
-
Combining fecal immunochemical testing and questionnaire-based risk assessment in selecting participants for colonoscopy screening in the Chinese National Colorectal Cancer Screening Programs: A population-based cohort study.PLoS Med. 2024 Feb 22;21(2):e1004340. doi: 10.1371/journal.pmed.1004340. eCollection 2024 Feb. PLoS Med. 2024. PMID: 38386617 Free PMC article.
-
Veterans Health Administration enrollees' choice of care setting relates to the expansion of care options: Evidence from screening colonoscopies before and after the MISSION Act.Health Serv Res. 2024 Feb;59(1):e14241. doi: 10.1111/1475-6773.14241. Epub 2023 Sep 26. Health Serv Res. 2024. PMID: 37750415 Free PMC article.
References
-
- Saini SD, Powell AA, Dominitz JA, Fisher DA, Francis J, Kinsinger L, Pittman KS, Schoenfeld P, Moser SE, Vijan S, Kerr EA. Developing and testing an electronic measure of screening colonoscopy overuse in a large integrated healthcare system. J Gen Intern Med. 2016; 31(Supp l) 1:53–60. - PMC - PubMed