Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2022 Oct 15;30(20):e1319-e1326.
doi: 10.5435/JAAOS-D-21-01063. Epub 2022 Jun 29.

Randomized Trial of Postoperative Venous Thromboembolism Prophylactic Compliance: Aspirin and Mobile Compression Pumps

Affiliations
Randomized Controlled Trial

Randomized Trial of Postoperative Venous Thromboembolism Prophylactic Compliance: Aspirin and Mobile Compression Pumps

Matthew J Dietz et al. J Am Acad Orthop Surg. .

Abstract

Background: Aspirin, as a routine venous thromboembolism (VTE) prophylaxis, is approved along with pneumatic compression pumps by the American College of Chest Physicians. We assessed compliance of aspirin and pump use after total joint arthroplasty.

Methods: A randomized trial of aspirin alone or aspirin/mobile compression pumps after total joint arthroplasty was performed. Aspirin and pump compliance, VTE events, and satisfaction with pump use were collected. Compliance was assessed through an internal device monitor and drug log book. Patients were also contacted 90 days postoperatively for reported symptomatic VTEs.

Results: Each group had 40 patients and greater than 94% compliance with aspirin use, with no difference between groups (P = 0.55). Overall pump compliance during the first 14 days after hospital discharge was 51% (SD ± 33), which was significantly worse than aspirin compliance at 99% (SD ± 4.1) (P < 0.0001). Only 10 patients were compliant (>20 hr/d) with recommended pump use throughout the entire recommended period. There was no notable association between aspirin compliance and VTE within 90 days. There was no notable association between pump compliance and VTE at 90 days. However, average pump use compliance was 20% in patients with VTE and 54% in patients without VTE within 90 days. With the numbers available in this compliance study, there was no significant difference (P = 0.11).

Discussion: Aspirin compliance was notably greater than pump compliance. In this study, we found that pump compliance was not associated with lower VTE risk. In fact, no increased risk was recognized in patients with an average pump usage of >50%. Further study is warranted to define the duration of pump use required for clinical significance. The recommended use of compression pumps should continue to be examined.

PubMed Disclaimer

References

    1. Colwell CW Jr, Froimson MI, Anseth SD, et al.: A mobile compression device for thrombosis prevention in hip and knee arthroplasty. J Bone Joint Surg Am 2014;96:177-183.
    1. Falck-Ytter Y, Francis CW, Johanson NA, et al.: Prevention of VTE in orthopedic surgery patients: Antithrombotic Therapy and Prevention of Thrombosis, 9th ed: American College of Chest Physicians Evidence-Based Clinical Practice Guidelines. Chest 2012;141(2 suppl):e278S-e325S.
    1. Edwards JZ, Pulido PA, Ezzet KA, Copp SN, Walker RH, Colwell CW Jr: Portable compression device and low-molecular-weight heparin compared with low-molecular-weight heparin for thromboprophylaxis after total joint arthroplasty. J Arthroplasty 2008;23:1122-1127.
    1. Colwell CW Jr: Thrombosis prevention in lower extremity arthroplasty: Mobile compression device or pharmacological therapy. Surg Technol Int 2014;25:233-238.
    1. Mont MA, Jacobs JJ: AAOS clinical practice guideline: Preventing venous thromboembolic disease in patients undergoing elective hip and knee arthroplasty. J Am Acad Orthop Surg 2011;19:777-778.

Publication types

MeSH terms