Utilization of 18s ribosomal RNA LAMP for detecting Plasmodium falciparum in microscopy and rapid diagnostic test negative patients
- PMID: 36201568
- PMCID: PMC9536604
- DOI: 10.1371/journal.pone.0275052
Utilization of 18s ribosomal RNA LAMP for detecting Plasmodium falciparum in microscopy and rapid diagnostic test negative patients
Abstract
In this study, Plasmodium falciparum was detected in patients that were declared negative for malaria microscopy and rapid diagnostic test kit (mRDT), using Plasmodium 18s rRNA loop-mediated isothermal amplification (LAMP) technique. The main aim of this study was to assess the usefulness of LAMP assay for detecting pre-clinical malaria, when microscopy and mRDT were less sensitive. DNA was obtained from 100 μL of whole blood using the boil and spin method. Subsequently, the Plasmodium 18s rRNA LAMP assay was performed to amplify the specific Plasmodium 18s rRNA gene. Microscopy and mRDT negative samples [697/2223 (31.2%)] were used for this study. Compared to frequencies obtained for the other demographic variables, most of the patients were < 6 years (37.7%), females (59.0%), peri-urban dwellers (39.0%) and patients that sought outpatient department services (39.3%). Overall, the prevalence of Plasmodium 18s rRNA was 17.5%. when stratified by study variables, Plasmodium 18s rRNA LAMP positivity was higher in patients over 30 years [58/122 (54.2%)], males [69/122 (56.5%)], rural dwellers [69/122 (56.5%)] and patients that sought OPD services [68/122 (55.7%)]. The risk of being infected with Plasmodium when routine tests were negative was higher in 15-30-year group (OR = 3.03, 95% CI: 1.6-5.8, p = 0.0007), patients > 30 years (OR = 15.2, 95% CI: 8.3-27.7, p<0.001), males (OR = 2.1, 95% CI: 1.4-3.2, p = 0.0002) and rural dwellers (OR = 2.2, 95% CI:1.4-3.6, p = 0.0009). However, risk was lower in post-natal children (OR = 0.3, 95% CI: 0.18-0.51, p<0.001). Majority (81.5%) of the infected patients presented with headache, herpes labialis, diarrhea and vomiting. We demonstrated the lack of sensitivities of microscopy and mRDT for one-time diagnosis of malaria. Therefore, it is essential to utilize a sensitive technique such as Plasmodium 18s rRNA LAMP to increase the detection rate of Plasmodium infection.
Conflict of interest statement
The authors have declared that no competing interests exist.
Figures
References
-
- Badmos AO, Alaran AJ, Adebisi YA, Bouaddi O, Onibon Z, Dada A, et al. What sub-Saharan African countries can learn from malaria elimination in China. Trop Med Health [Internet]. 2021. Dec 24;49(1):86. Available from: https://tropmedhealth.biomedcentral.com/articles/10.1186/s41182-021-00379-z - DOI - PMC - PubMed
-
- Cunningham J, Jones S, Gatton ML, Barnwell JW, Cheng Q, Chiodini PL, et al. A review of the WHO malaria rapid diagnostic test product testing programme (2008–2018): performance, procurement and policy. Malar J [Internet]. 2019. Dec 2;18(1):387. Available from: https://malariajournal.biomedcentral.com/articles/10.1186/s12936-019-3028-z - DOI - PMC - PubMed
-
- Wangai L, Karau M, Njiruh P, Sabah O, Kimani F, Magoma G, et al. Sensitivity of microscopy compared to molecular diagnosis of P. falciparum: Implications on malaria treatment in epidemic areas in Kenya. African J Infect Dis [Internet]. 2011. May 24;5(1). Available from: http://www.ajol.info/index.php/ajid/article/view/66504 doi: 10.4314/ajid.v5i1.66504 - DOI - PMC - PubMed
-
- Moody A. Rapid Diagnostic Tests for Malaria Parasites. Clin Microbiol Rev [Internet]. 2002. Jan;15(1):66–78. Available from: https://journals.asm.org/doi/10.1128/CMR.15.1.66-78.2002 - DOI - PMC - PubMed
-
- Payne D. Use and limitations of light microscopy for diagnosing malaria at the primary health care level. Bull World Health Organ [Internet]. 1988;66(5):621–6. Available from: http://www.ncbi.nlm.nih.gov/pubmed/2463112 - PMC - PubMed
MeSH terms
Substances
Supplementary concepts
LinkOut - more resources
Full Text Sources
Medical