Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2022 Sep;17(5):401-408.
doi: 10.1177/15569845221124113. Epub 2022 Oct 11.

Monitored Anesthesia Care Versus General Anesthesia for Transcatheter Aortic Valve Replacement

Affiliations

Monitored Anesthesia Care Versus General Anesthesia for Transcatheter Aortic Valve Replacement

Henry R Holmes et al. Innovations (Phila). 2022 Sep.

Abstract

Objective: Monitored anesthesia care (MAC) has been increasingly used in lieu of general anesthesia (GA) for transcatheter aortic valve replacement (TAVR). We sought to compare outcomes and in-hospital costs between MAC and GA for TAVR at a Veterans Affairs Medical Center.

Methods: A single-center retrospective review was performed of 349 patients who underwent transfemoral TAVR (MAC, n = 244 vs GA, n = 105) from January 2014 to December 2019. Baseline patient characteristics, operating room (OR) time, intensive care unit (ICU) length of stay (LOS), and cost, total LOS, hospital cost, total cost, and complication rates were collected. Propensity matching was performed and resulted in 83 matched pairs.

Results: In the unmatched TAVR cohort, MAC TAVR was associated with reduced OR time (146 vs 198 min, P < 0.001), ICU LOS (1.4 vs 1.8 days, P < 0.001), total hospital LOS (3.4 vs 5.4 days, P < 0.001), and lower index total cost ($81,300 vs $85,400, P = 0.010). After propensity matching, MAC TAVR patients had reduced OR time (146 vs 196 min, P < 0.05), ICU LOS (1.2 vs 1.7 days, P = 0.006), total LOS (3.5 vs 5.1 days, P = 0.001), and 180-day mortality (2.4% vs 12%, P < 0.03). There was no difference in total hospitalization cost or total cost.

Conclusions: In propensity-matched groups, TAVR utilizing MAC is associated with improved OR time efficiency, decreased LOS, and a reduction in 180-day mortality but no significant difference in cost.

Keywords: cardiac anesthesia; cost analysis; endovascular procedures; quality improvement; transcatheter aortic valve replacement.