Noninvasive, automatic 24-h ambulatory blood pressure monitoring in normotensive subjects
- PMID: 3622479
- DOI: 10.1007/BF00417763
Noninvasive, automatic 24-h ambulatory blood pressure monitoring in normotensive subjects
Abstract
The reliability of noninvasive, automatic blood pressure monitoring is not yet clearly established. A 24-h ambulatory blood pressure profile was obtained in 9 healthy, normotensive subjects with an automatic, noninvasive device. The blood pressure profile showed the typical circadian pattern with lower systolic and diastolic values during sleep, although pulse pressure was fairly constant (about 40 mm Hg). The systolic blood pressure rose steeply in the early morning hours--before waking up. The results were compared with simultaneous hourly readings using the auscultatory method. There were no statistically significant differences between the automatic and auscultatory readings, 13 of the 18 mean values at different time points being within 2 mm Hg of each other. All the auscultatory means fell within the 95% confidence limits of those measured hourly by the automatic method. Although the automatic method seemed to be reliable compared with the auscultatory method, its sensitivity to motion artifacts is a disadvantage in a truly ambulatory setting.
Similar articles
-
Noninvasive ambulatory blood pressure control in normotensive pregnant women.Am J Hypertens. 1989 Dec;2(12 Pt 1):924-6. doi: 10.1093/ajh/2.12.924. Am J Hypertens. 1989. PMID: 2610998
-
[Can ambulatory blood pressure be assessed using 9 self-measurements?].Arch Mal Coeur Vaiss. 1986 Jun;79(6):896-900. Arch Mal Coeur Vaiss. 1986. PMID: 3099708 French.
-
Automated ambulatory blood pressure monitoring: a study in age-matched normotensive and hypertensive men.Am Heart J. 1985 Jun;109(6):1334-8. doi: 10.1016/0002-8703(85)90361-8. Am Heart J. 1985. PMID: 4003244
-
Ambulatory blood pressure monitoring: methodologic issues.Am J Nephrol. 1996;16(3):190-201. doi: 10.1159/000168998. Am J Nephrol. 1996. PMID: 8739878 Review.
-
Measuring arterial blood pressure in humans: Auscultatory and automatic measurement techniques for human biological field studies.Am J Hum Biol. 2018 Jan;30(1). doi: 10.1002/ajhb.23063. Epub 2017 Sep 22. Am J Hum Biol. 2018. PMID: 28940503 Review.
Cited by
-
The circadian heart rate but not blood pressure profile is influenced by the timing of beta-blocker administration in hypertensives.Eur J Clin Pharmacol. 1991;40(4):435-6. doi: 10.1007/BF00265862. Eur J Clin Pharmacol. 1991. PMID: 2050184 No abstract available.