Risk factors for Ex-Press® surgery failure

Affiliations

Risk factors for Ex-Press® surgery failure

Mitsuya Otsuka et al. Int Ophthalmol. 2023 May.

Abstract

Purpose: To investigate the risk factors for Ex-Press® (EXP) surgery failure.

Patients and methods: This was a retrospective non-randomized study of 98 patients who had undergone EXP and were followed up ≥ 5 years. We investigated the following nine risk factors: age, gender, hypertension, diabetes mellitus (DM), previous glaucoma surgery, type of glaucoma (primary open-angle glaucoma vs. pseudo-exfoliation glaucoma), surgical methods (EXP alone vs. EXP + cataract surgery simultaneously), central corneal thickness (CCT), and preoperative intraocular pressure (IOP). We defined a successful surgery as a postoperative reduction in the IOP ≥ 20% from the preoperative IOP and ≤ 18 mmHg. We determined the risk factors using multivariate cox regression models.

Results: Performing EXP significantly decreased the IOP (preoperative: 25.2 ± 8.7, at 5 years: 11.1 ± 4.1). The success ratio of EXP was 67.4% at 5 years. We found no significant risk factors for EXP surgery failure. The p values of the factors were age (p = 0.936), gender (p = 0.0587), hypertension (p = 0.409), DM (p = 0.967), previous glaucoma surgery (p = 0.940), type of glaucoma (p = 0.435) surgical methods (p = 0.521), CCT (p = 0.091), and preoperative IOP (p = 0.082).

Conclusions: No preoperative factors that could be used to predict the failure of EXP surgery were identified. EXP can be safely performed for primary open-angle glaucoma and pseudo-exfoliation glaucoma.

Keywords: 5 years; Ex-Press; Glaucoma; Risk factor; Surgical outcome.

PubMed Disclaimer

References

    1. Arimura S, Miyake S, Iwasaki K, Gozawa M, Matsumura T, Takamura Y et al (2018) Randomised clinical trial for postoperative complications after Ex-Press implantation versus trabeculectomy with 2-year follow-up. Sci Rep 8(1):16168. https://doi.org/10.1038/s41598-018-34627-w - DOI - PubMed - PMC
    1. Netland PA, Sarkisian SR Jr, Moster MR, Ahmed II, Condon G, Salim S et al (2014) Randomized, prospective, comparative trial of Ex-Press glaucoma filtration device versus trabeculectomy (XVT study). Am J Ophthalmol 157(2):433-440 e3. https://doi.org/10.1016/j.ajo.2013.09.014 - DOI - PubMed
    1. Ishida K, Moroto N, Murata K, Yamamoto T (2017) Effect of glaucoma implant surgery on intraocular pressure reduction, flare count, anterior chamber depth, and corneal endothelium in primary open-angle glaucoma. Jpn J Ophthalmol 61(4):334–346. https://doi.org/10.1007/s10384-017-0512-2 - DOI - PubMed
    1. Wagschal LD, Trope GE, Jinapriya D, Jin YP, Buys YM (2015) Prospective randomized study comparing Ex-Press to trabeculectomy: 1-year results. J Glaucoma 24(8):624–629. https://doi.org/10.1097/IJG.0000000000000029 - DOI - PubMed
    1. Wang W, Zhang X (2014) Meta-analysis of randomized controlled trials comparing Ex-Press implantation with trabeculectomy for open-angle glaucoma. PLoS ONE 9(6):e100578. https://doi.org/10.1371/journal.pone.0100578 - DOI - PubMed - PMC

LinkOut - more resources