. 2022 Oct 7;15(19):6968.
doi: 10.3390/ma15196968.

Retentive Strength of CAD/CAM-Fabricated All-Ceramic Crowns Luted on Titanium Implant Abutments Using Different Ceramic Materials and Luting Agents: An In Vitro Study

Affiliations

Retentive Strength of CAD/CAM-Fabricated All-Ceramic Crowns Luted on Titanium Implant Abutments Using Different Ceramic Materials and Luting Agents: An In Vitro Study

Monika Bjelopavlovic et al. Materials (Basel). .

Abstract

Objectives: This study aimed to determine the retentive strength of monolithic hybrid-all-ceramic crowns luted on titanium implant abutments. Material and Methods: In total, 450 crowns (75 each of Mark II, Empress CAD, e.max CAD, Suprinity, Enamic, Celtra Duo) were milled using a CAD/CAM system. The crowns were cemented onto sandblasted titanium implant abutments using five luting agents (Multilink Implant, Variolink II, RelyX Unicem, Fujicem, and Panavia 2.0). After thermocycling was performed (5000 cycles: 5−55 °C, 30-s dwell time), the crowns were removed using a universal testing machine. The location of luting-agent residue on the abutment and inner crown surfaces was evaluated. Analyses of variance (ANOVA) with the Bonferroni correction were performed to evaluate differences of retentive strength depending on the crown material and the kind of the luting agent. Results: The retentive strengths for the different ceramic materials were Vita Mark II: 652N-759N (SD:134N-146N), Empress CAD: 681N-822N (SD: 89N-146N), e.max CAD: 784N-1044N (SD: 109N-176N), Vita Enamic: 716N-1177N (SD: 132N-220N), Vita Suprinity: 867N-1488N (SD: 202N-278N), and Celtra Duo 772N-1335N (SD:151N-229N). After the removal trials, the visual documentation showed different adhesive residue location depending on the ceramic materials. Furthermore, the pull-off force was dependent on the choice of adhesives. No significant differences were found between different luting agents and the ceramic material Vita Mark II and Empress CAD. EmaxCAD showed significant differences with Unicem and FujiCem compared to Panavia, as did VitaSuprinity, VitaEnamic, and Celtra Duo (p < 0.001). Conclusions: The ceramic material used seems to influence the retentive strength and the use of certain luting agents results in a higher retentive strength for some ceramic materials.

Keywords: CAD/CAM; cement; ceramic; implant; luting agent; retentive strength.

PubMed Disclaimer

Conflict of interest statement

The authors declare no conflict of interest.

Figures

Figure A1
Figure A1
Schematic representation of the methodology.
Figure 1
Figure 1
Retentive forces of various ceramic materials luted with different luting agents.

References

    1. Kunavisarut C., Jarangkul W., Pornprasertsuk-Damrongsri S., Joda T. Patient-reported outcome measures (PROMs) comparing digital and conventional workflows for treatment with posterior single-unit implant restorations: A randomized controlled trial. J. Dent. 2022;117:103875. doi: 10.1016/j.jdent.2021.103875. - DOI - PubMed
    1. Joda T., Ferrari M., Bragger U., Zitzmann N.U. Patient Reported Outcome Measures (PROMs) of posterior single-implant crowns using digital workflows: A randomized controlled trial with a three-year follow-up. Clin. Oral Implant. Res. 2018;29:954–961. doi: 10.1111/clr.13360. - DOI - PubMed
    1. Michelinakis G., Apostolakis D., Kamposiora P., Papavasiliou G., Ozcan M. The direct digital workflow in fixed implant prosthodontics: A narrative review. BMC Oral Health. 2021;21:37. doi: 10.1186/s12903-021-01398-2. - DOI - PMC - PubMed
    1. Vichitgomen J., Srisawasdi S. Deep margin elevation with resin composite and resin-modified glass-ionomer on marginal sealing of CAD-CAM ceramic inlays: An in vitro study. Am. J. Dent. 2021;34:327–332. - PubMed
    1. Lehmann K.M., Weyhrauch M., Bjelopavlovic M., Scheller H., Staedt H., Ottl P., Kaemmerer P.W., Wentaschek S. Marginal and Internal Precision of Zirconia Four-Unit Fixed Partial Denture Frameworks Produced Using Four Milling Systems. Materials. 2021;14:2663. doi: 10.3390/ma14102663. - DOI - PMC - PubMed