Design and Characterisation of an Optical Fibre Dosimeter Based on Silica Optical Fibre and Scintillation Crystal
- PMID: 36236411
- PMCID: PMC9572585
- DOI: 10.3390/s22197312
Design and Characterisation of an Optical Fibre Dosimeter Based on Silica Optical Fibre and Scintillation Crystal
Abstract
In nuclear power plants, particle accelerators, and other nuclear facilities, measuring the level of ionising gamma radiation is critical for the safety and management of the operation and the environment's protection. However, in many cases, it is impossible to monitor ionising radiation directly at the required location continuously. This is typically either due to the lack of space to accommodate the entire dosimeter or in environments with high ionising radiation activity, electromagnetic radiation, and temperature, which significantly shorten electronics' lifetime. To allow for radiation measurement in such scenarios, we designed a fibre optic dosimeter that introduces an optical fibre link to deliver the scintillation radiation between the ionising radiation sensor and the detectors. The sensors can thus be placed in space-constrained and electronically hostile locations. We used silica optical fibres that withstand high radiation doses, high temperatures, and electromagnetic interference. We use a single photon counter and a photomultiplier to detect the transmitted scintillation radiation. We have shown that selected optical fibres, combined with different scintillation materials, are suitable for measuring gamma radiation levels in hundreds of kBq. We present the architecture of the dosimeter and its experimental characterisation with several combinations of optical fibres, detectors, and scintillation crystals.
Keywords: dosimetry; fibre sensors; gamma radiation measurement; ionising radiation detection; silica optical fibres.
Conflict of interest statement
The authors declare no conflict of interest.
Figures










References
-
- Knoll G.F. Radiation Detection and Measurement. 4th ed. Wiley; New York, NY, USA: 2010.
-
- Nguyen L.V., Schartner E.P., Otten D., Yu Z., Lancaster D., Ebendorff-Heidepriem H., Warren-Smith S.C. Multi-point optical fiber pressure sensor; Proceedings of the AOS Australian Conference on Optical Fibre Technology (ACOFT)/Australian Conference on Optics, Lasers, and Spectroscopy (ACOLS); Melbourne, VIC, Australia. 9–12 December 2019.
-
- Mikel B., Helan R., Buchta Z., Jelinek M., Cip O. Preparation and measurement of FBG based length, temperature and vibration sensors; Proceedings of the 20th Slovak-Czech-Polish Optical Conference on Wave and Quantum Aspects of Contemporary Optics; Jasna, Slovakia. 5–9 September 2016;
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources