. 2022 Dec;17(12):2211-2219.
doi: 10.1007/s11548-022-02774-1. Epub 2022 Oct 17.

Using multiple images and contours for deformable 3D-2D registration of a preoperative CT in laparoscopic liver surgery

Affiliations

Using multiple images and contours for deformable 3D-2D registration of a preoperative CT in laparoscopic liver surgery

Yamid Espinel et al. Int J Comput Assist Radiol Surg. 2022 Dec.

Abstract

Purpose: Laparoscopic liver resection is a challenging procedure because of the difficulty to localise inner structures such as tumours and vessels. Augmented reality overcomes this problem by overlaying preoperative 3D models on the laparoscopic views. It requires deformable registration of the preoperative 3D models to the laparoscopic views, which is a challenging task due to the liver flexibility and partial visibility.

Methods: We propose several multi-view registration methods exploiting information from multiple views simultaneously in order to improve registration accuracy. They are designed to work on two scenarios: on rigidly related views and on non-rigidly related views. These methods exploit the liver's anatomical landmarks and texture information available in all the views to constrain registration.

Results: We evaluated the registration accuracy of our methods quantitatively on synthetic and phantom data, and qualitatively on patient data. We measured 3D target registration errors in mm for the whole liver for the quantitative case, and 2D reprojection errors in pixels for the qualitative case.

Conclusion: The proposed rigidly related multi-view methods improve registration accuracy compared to the baseline single-view method. They comply with the 1 cm oncologic resection margin advised for hepatocellular carcinoma interventions, depending on the available registration constraints. The non-rigidly related multi-view method does not provide a noticeable improvement. This means that using multiple views with the rigidity assumption achieves the best overall registration error.

Keywords: Augmented reality; Laparoscopy; Liver; Registration.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Koo B, Ozgur E, Le Roy B, Buc E, Bartoli A (2017) Deformable registration of a preoperative 3D liver volume to a laparoscopy image using contour and shading cues. In: MICCAI
    1. Adagolodjo Y, Trivisonne R, Haouchine N, Cotin S, Courtecuisse H (2017) Silhouette-based pose estimation for deformable organs application to surgical augmented reality. In: IROS
    1. Modrzejewski R, Collins T, Seeliger B, Bartoli A, Hostettler A, Marescaux J (2019) An in vivo porcine dataset and evaluation methodology to measure soft-body laparoscopic liver registration accuracy with an extended algorithm that handles collisions. In: IPCAI
    1. Chen L, Tang W, John NW, Wuan TR, Zhang JJ (2018) SLAM-based dense surface reconstruction in monocular minimally invasive surgery and its application to augmented reality. Comput Methods Programs Biomed 158:135–146 - DOI - PubMed
    1. Haouchine N, Roy F, Untereiner L, Cotin S (2016) Using contours as boundary conditions for elastic registration during minimally invasive hepatic surgery. In: IROS

MeSH terms

LinkOut - more resources