Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2022 Oct;8(10):1304-1314.
doi: 10.1016/j.jacep.2022.06.024. Epub 2022 Sep 28.

Sex Differences in Outcomes of Tetralogy of Fallot Patients With Implantable Cardioverter-Defibrillators

Affiliations
Free article

Sex Differences in Outcomes of Tetralogy of Fallot Patients With Implantable Cardioverter-Defibrillators

Victor Waldmann et al. JACC Clin Electrophysiol. 2022 Oct.
Free article

Abstract

Background: Women with congenital heart disease at high risk for sudden cardiac death have been poorly studied thus far.

Objectives: The aim of this study was to assess sex-related differences in patients with tetralogy of Fallot (TOF) and implantable cardioverter-defibrillators (ICDs).

Methods: Data were analyzed from the DAI-T4F (French National Registry of Patients With Tetralogy of Fallot and Implantable Cardioverter Defibrillator) cohort study, which has prospectively enrolled all patients with TOF with ICDs in France since 2010. Clinical events were centrally adjudicated by a blinded committee.

Results: A total of 165 patients (mean age 42.2 ± 13.3 years) were enrolled from 40 centers, including 49 women (29.7%). Among the 9,692 patients with TOF recorded in the national database, the proportion of women with ICDs was estimated to be 1.1% (95% CI: 0.8%-1.5%) vs 2.2% (95% CI: 1.8%-2.6%) in men (P < 0.001). The clinical profiles of patients at implantation, including the number of risk factors for ventricular arrhythmias, were similar between women and men. During a median follow-up period of 6.8 years (IQR: 2.5-11.4 years), 78 patients (47.3%) received at least 1 appropriate ICD therapy, without significant difference in annual incidences between women (12.1%) and men (9.9%) (HR: 1.22; 95% CI: 0.76-1.97; P = 0.40). The risk for overall ICD-related complications was similar in women and men (HR: 1.33; 95% CI: 0.81-2.19; P = 0.30), with 24 women (49.0%) experiencing at least 1 complication.

Conclusions: Our findings suggest that women with TOF at high risk for sudden cardiac death have similar benefit/risk balance from ICD therapy compared with men. Whether ICD therapy is equally offered to at-risk women vs men warrants further evaluation in TOF as well as in other congenital heart disease populations. (French National Registry of Patients With Tetralogy of Fallot and Implantable Cardioverter Defibrillator [DAI-T4F]; NCT03837574).

Keywords: congenital heart disease; implantable cardioverter-defibrillator; sex; sudden death; tetralogy of Fallot; ventricular arrhythmia; women.

PubMed Disclaimer

Conflict of interest statement

Funding Support and Author Disclosures This work was supported by the French Institute of Health and Medical Research, Fédération Française de Cardiologie, and Société Française de Cardiologie. The authors have reported that they have no relationships relevant to the contents of this paper to disclose.

Comment in

Publication types

Associated data