. 2022 Dec;37(12):4654-4661.
doi: 10.1111/jocs.17048. Epub 2022 Oct 23.

Hemodynamic follow-up after valve-in-valve TAVR for failed aortic bioprosthesis

Affiliations

Hemodynamic follow-up after valve-in-valve TAVR for failed aortic bioprosthesis

Manuel Wilbring et al. J Card Surg. 2022 Dec.

Abstract

Background: "valve-in-valve" TAVR (VIV-TAVR) is established and provides good initial clinical and hemodynamic outcomes. Lacking long-term durability data baffle the expand to lower risk patients. For those purposes, the present study adds a hemodynamic 3-years follow-up.

Methods: A total of 77 patients underwent VIV-TAVR for failing aortic bioprosthesis during a 7-years period. Predominant mode of failure was stenosis in 87.0%. Patients had a mean age of 79.4 ± 5.8 years and a logistic EuroSCORE of 30.8 ± 15.7%. The Society of Thoracic Surgeons-PROM averaged 5.79 ± 2.63%. Clinical results and hemodynamic outcomes are reported for 30-days, 1-, 2-, and 3-years. Completeness of follow-up was 100% with 44 patients at risk after 3-years. Follow-up ranged up to 7.1 years.

Results: Majority of the surgical valves were stented (94.8%) with a mean labeled size of 23.1 ± 2.3 mm and true-ID of 20.4 ± 2.6 mm. A true-ID ≤21 mm had 58.4% of the patients. Self-expanding valves were implanted in 68.8% (mean labeled size 24.1 ± 1.8 mm) and balloon-expanded in 31.2% (mean size 24.1 ± 1.8 mm). No patient died intraoperatively. Hospital mortality was 1.3% and three-years survival 57.1%. All patients experienced an initial significant dPmean-reduction to 16.8 ± 7.1 mmHg. After 3-years mean dPmean raised to 26.0 ± 12.2 mmHg. This observation was independent from true-ID or type of transcatheter aortic valve replacement (TAVR)-prosthesis. Patients with a true-ID ≤21 mm had a higher initial (18.3 ± 5.3 vs. 14.9 ± 7.1 mmHg; p = .005) and dPmean after 1-year (29.2 ± 8.2 vs. 13.0 ± 6.7 mmHg; p = .004). There were no significant differences in survival.

Conclusions: VIV-TAVR is safe and effective in the early period. In surgical valves with a true-ID ≤21 mm inferior hemodynamic and survival outcomes must be expected. Nonetheless, also patients with larger true-IDs showed steadily increasing transvalvular gradients. This raises concern about durability.

Keywords: TAVI; TAVR; aortic valve; redo; valve-in-valve.

PubMed Disclaimer

References

REFERENCES

    1. Wilbring M, Alexiou K, Tugtekin SM, et al. Transapical transcatheter valve-in-valve implantation for deteriorated mitral valve bioprostheses. Ann Thorac Surg. 2013;95(1):111-117.
    1. Wilbring M, Alexiou K, Tugtekin SM, et al. Transcatheter valve-in-valve therapies: patient selection, prosthesis assessment and selection, results, and future directions. Curr Cardiol Rep. 2013;15(3):341.
    1. Wilbring M, Sill B, Tugtekin SM, et al. Transcatheter valve-in-valve implantation for deteriorated aortic bioprosthesis: initial clinical results and follow-up in a series of high-risk patients. Ann Thorac Surg. 2012;93(3):734-741.
    1. Cribier A, Eltchaninoff H, Bash A, et al. Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description. Circulation. 2002;106(24):3006-3008.
    1. Seiffert M, Conradi L, Baldus S, et al. Transcatheter mitral valve-in-valve implantation in patients with degenerated bioprostheses. JACC Cardiovasc Interv. 2012;5(3):341-349.

LinkOut - more resources