Evaluation of shear bond strength and adhesive remnant index of metal APC™ Flash-Free adhesive system: A comparative in vitro study with APC™ II and uncoated metal brackets
- PMID: 36280583
- DOI: 10.1016/j.ortho.2022.100705
Evaluation of shear bond strength and adhesive remnant index of metal APC™ Flash-Free adhesive system: A comparative in vitro study with APC™ II and uncoated metal brackets
Abstract
Objective: The aim of this in vitro study was to compare the shear bond strength (SBS) and the adhesive remnant index (ARI) of the metal APC™ Flash-Free adhesive system, the APC™ pre-coated adhesive system and a conventional uncoated system.
Materials and methods: One hundred eighty-six freshly extracted human premolars were randomly divided into 3 groups and bonded by a single operator. Group A/Control Group (60 teeth): the manual bonding group treated with Transbond™ XT Light Cure Adhesive Paste (3M™ Unitek). Group B (60 teeth): treated with APC™II metal maxillary premolar precoated brackets. Group C (66 teeth): treated with metal maxillary premolar APC Flash-Free brackets. The teeth were then stored in distilled water at 37̊C for 24hours, and five hundred cycles of thermocycling were performed. The Shear Bond Strength (SBS) test was performed using an Instron Universal Testing Machine, and the adhesive remnant index (ARI) was determined using a dental optical microscope at ×25 magnification.
Results: The mean shear bond strength values showed differences between the three types of brackets (P=0.016; Anova). It was significantly higher with APC™II and lower with APC Flash-Free brackets; however, no significant differences were found between conventional and APC Flash-Free brackets (P-value=0.574). The distribution of the dichotomized ARI score was significantly different between the three brackets (P-value=0.049). The ARI score for APC Flash-Free brackets was higher with no significant difference between the conventional system and APC brackets (P-value=0.361).
Conclusions: The mean SBS values were not significantly different between APC Flash-Free metal brackets and uncoated metal brackets. The APC Flash-Free metal system's bond failure occurred at the bracket-adhesive interface, with the highest percentage of teeth having more than 50% of the residual composite on the enamel after debonding.
Keywords: Adhesive remnant index; Flash-Free; Precoated brackets; Shear bond strength.
Copyright © 2022 Elsevier Masson SAS. All rights reserved.
Similar articles
-
Shear bond strength of adhesive precoated brackets: A comparative in vitro study.Int Orthod. 2023 Jun;21(2):100752. doi: 10.1016/j.ortho.2023.100752. Epub 2023 Apr 14. Int Orthod. 2023. PMID: 37062199
-
[Comparative study of excess glue around metallic APC™ Flash-Free adhesive system].Orthod Fr. 2022 Sep 1;93(3):249-258. doi: 10.1684/orthodfr.2022.91. Orthod Fr. 2022. PMID: 36217584 Clinical Trial. French.
-
Bond strength of pre-coated flash-free adhesive ceramic brackets. An in vitro comparative study on the second mandibular premolars.Int Orthod. 2018 Sep;16(3):425-439. doi: 10.1016/j.ortho.2018.06.017. Epub 2018 Jul 10. Int Orthod. 2018. PMID: 30006079
-
The Effect of Thermocycling on the Shear Bond Strength of Flash-free Brackets and Healing Dynamics of Enamel Microcracks: An In vitro Study.J Contemp Dent Pract. 2024 Sep 1;25(9):836-845. doi: 10.5005/jp-journals-10024-3746. J Contemp Dent Pract. 2024. PMID: 39791410
-
The Influence of Resin Infiltration on the Shear Bond Strength of Orthodontic Brackets: A Systematic Review and Meta-Analysis.J Funct Biomater. 2025 Jan 17;16(1):32. doi: 10.3390/jfb16010032. J Funct Biomater. 2025. PMID: 39852588 Free PMC article. Review.
Cited by
-
In vivo comparative assessment of bracket bond failure rates of single-component adhesives.J Int Soc Prev Community Dent. 2024 Apr 29;14(2):105-111. doi: 10.4103/jispcd.jispcd_44_23. eCollection 2024 Mar-Apr. J Int Soc Prev Community Dent. 2024. PMID: 38827357 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources