Case Reports
. 2023 Feb;10(1):716-720.
doi: 10.1002/ehf2.14219. Epub 2022 Oct 25.

Pressures do not equal volumes: implications for heart failure management in patients with CardioMEMS

Affiliations
Case Reports

Pressures do not equal volumes: implications for heart failure management in patients with CardioMEMS

Muhammad Shahzeb Khan et al. ESC Heart Fail. 2023 Feb.

Abstract

Pulmonary arterial pressures are often used as surrogates for intravascular blood volume. However, the relationship between pressure and volume remains controversial. To contextualize and provide concrete examples and impact on clinical management, we report two cases of heart failure (one in heart failure with reduced ejection fraction and one in heart failure with preserved ejection fraction) where pressure-based measurements did not accurately represent the intravascular status and affected clinical management.

Keywords: CardioMEMS; Heart failure; Pressure; Volume.

PubMed Disclaimer

Conflict of interest statement

Dr Fudim was supported by the National Heart, Lung, and Blood Institute (NHLBI) (K23HL151744), the American Heart Association (20IPA35310955), Bayer, Bodyport, BTG Specialty Pharmaceuticals, and Verily. He receives consulting fees from Abbott, Alleviant, Audicor, AxonTherapies, Bayer, Bodyguide, Bodyport, Boston Scientific, Coridea, CVRx, Daxor, Deerfield Catalyst, Edwards LifeSciences, Feldschuh Foundation, Fire1, Gradient, Intershunt, Medtronic, NXT Biomedical, Pharmacosmos, PreHealth, Shifamed, Splendo, Vironix, Viscardia, and Zoll.

Figures

Figure 1
Figure 1
Recordings from CardioMEMS for Case 1. The figure shows the implant time, and changes in pulmonary artery pressures after that. PA, pulmonary artery.
Figure 2
Figure 2
Recordings from CardioMEMS for Case 2. The figure shows the implant time, and changes in pulmonary artery pressures after that. PA, pulmonary artery.

References

    1. Greene SJ, Khan MS. Practical and evidence‐based approaches to in‐hospital decongestion for heart failure: Are we there yet? JACC Heart Fail. 2021; 9: 649–652. - PubMed
    1. Lindenfeld J, Zile MR, Desai AS, Bhatt K, Ducharme A, Horstmanshof D, Krim SR, Maisel A, Mehra MR, Paul S, Sears SF, Sauer AJ, Smart F, Zughaib M, Castaneda P, Kelly J, Johnson N, Sood P, Ginn G, Henderson J, Adamson PB, Costanzo MR. Haemodynamic‐guided management of heart failure (GUIDE‐HF): A randomised controlled trial. Lancet. 2021; 398: 991–1001. - PubMed
    1. Abraham WT, Adamson PB, Bourge RC, Aaron MF, Costanzo MR, Stevenson LW, Strickland W, Neelagaru S, Raval N, Krueger S, Weiner S, Shavelle D, Jeffries B, Yadav JS, CHAMPION Trial Study Group . Wireless pulmonary artery haemodynamic monitoring in chronic heart failure: A randomised controlled trial. Lancet. 2011; 377: 658–666. - PubMed
    1. https://abbott.mediaroom.com/2022‐02‐21‐Abbotts‐CardioMEMS‐TM‐HF‐System‐... (Accessed 8th May 2022).
    1. Yaranov DM, Jefferies JL, Silver MA, Burkhoff D, Rao VN, Fudim M. Discordance of pressure and volume: Potential implications for pressure‐guided remote monitoring in heart failure. J Card Fail. 2022: 870–872. - PMC - PubMed

Publication types