Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 Mar;89(3):157-165.
doi: 10.23736/S0375-9393.22.16736-2. Epub 2022 Oct 26.

Efficacy of almitrine as a rescue therapy for refractory hypoxemia in COVID and non-COVID acute respiratory distress syndrome. A retrospective monocenter study

Affiliations

Efficacy of almitrine as a rescue therapy for refractory hypoxemia in COVID and non-COVID acute respiratory distress syndrome. A retrospective monocenter study

Pierre-Louis Blot et al. Minerva Anestesiol. 2023 Mar.

Abstract

Background: Almitrine, a drug enhancing hypoxic pulmonary vasoconstriction, has been proposed as a rescue therapy for refractory hypoxemia in COVID related acute respiratory distress syndrome (C-ARDS). We aimed at investigating the response to almitrine depending on the cause of ARDS (COVID vs. non-COVID).

Methods: Monocenter retrospective study from 2014 to 2021. All patients diagnosed with moderate to severe ARDS and treated with almitrine as rescue therapy for refractory hypoxemia were studied. Factor independently associated with oxygenation response to almitrine infusion were determined.

Results: Sixty patients with ARDS and treated with almitrine were analyzed, 36 (60%) due to SARS-CoV-2 infection and 24 (40%) due to other causes. Baseline PaO2/FiO2 was 78 [61-101] mmHg, 76% had at least one prone positioning before the start of almitrine infusion. Median PaO2/FiO2 increased by +38 [7-142] mmHg (+61% [10-151]) after almitrine infusion. PaO2/FiO2 increased by +134 [12-186] mmHg in non-COVID ARDS (NC-ARDS) and by +19 [8-87] mmHg in C-ARDS. The increase in PaO2/FiO2 was lower in C-ARDS than in NC-ARDS (P=0.013). In multivariable analysis, C-ARDS, non-invasive ventilation and concomitant use of norepinephrine were independently associated with a decreased oxygenation response to almitrine infusion.

Conclusions: Our study reports a highly variable response to almitrine infusion in ARDS patients with refractory hypoxemia. Independent factors associated with a reduced oxygenation response to almitrine infusion were: COVID ARDS, concomitant use of norepinephrine, and non-invasive ventilatory strategy.

PubMed Disclaimer

LinkOut - more resources