Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2022 Dec:170:111987.
doi: 10.1016/j.exger.2022.111987. Epub 2022 Oct 24.

Comparison of manual and automated measures of walking speed: Distance and pace matter

Affiliations
Free article

Comparison of manual and automated measures of walking speed: Distance and pace matter

Félicia Santos et al. Exp Gerontol. 2022 Dec.
Free article

Abstract

Background: Walking speed (WS) represents a global marker of individual health and provides a simple and objective measure of motor performances for use in clinical and research settings. WS is most often measured over relatively short distances at usual (UWS) or fast (FWS) pace, using manual (e.g., stopwatch) or automated methods (e.g., photoelectric cells). As the time needed to walk over these distances is very short, we hypothesized that measurement error related to manual compared to automated WS measures is more pronounced for shorter distances and FWS and investigated the reliability and agreement of WS in a subsample of the Constances cohort at two paces and over two distances.

Methods: We recruited 100 community-dwelling participants (50 % women) aged 45-70y (mean = 56.1y). WS was measured manually (stopwatches) and using photoelectric cells, at two paces (UWS/FWS) and over two distances (3 m/5 m). Agreement was examined using Bland and Altman plots and intraclass correlation coefficients (ICC).

Results: Participants were on average 169.8 cm tall, and their mean body mass index was 25.4 kg/m2. Agreement between manual stopwatches and photoelectric cells was excellent (ICCs between 0.92 and 0.97), but it was lower for smaller distances, with significantly lower ICCs over 3 m compared to 5 m both for UWS (differenceICC = -0.04) and FWS (differenceICC = -0.05). Bias of manual measures was constant for UWS and increased with increasing FWS. There were inter-rater effects, with better agreement for UWS and 5 m compared to FWS and 3 m.

Conclusions: Both distance and pace have an influence on the reliability of WS measures using manual timing methods. Our findings also suggest the presence of rater effects and better agreement for 5 m and UWS. These findings are helpful for the design of studies that include manual measures of WS, especially FWS, in order to reduce measurement error and suggest that longer distances are preferable.

Keywords: Agreement; Community-dwelling; Reliability; Walking speed.

PubMed Disclaimer

Conflict of interest statement

Declaration of competing interest FS is the recipient of a doctoral grant from Université Paris-Saclay, France. AO reports no conflicts of interest. ML reports no conflicts of interest. MZ reports no conflicts of interest. FA reports no conflicts of interest. AE has received research grants from Agence nationale de la recherche (ANR), France Parkinson, Anses, Michael J. Fox foundation outside this work.

Similar articles

Cited by

Publication types

LinkOut - more resources