Magnetic Resonance Current Density Imaging (MR-CDI)
- PMID: 36306097
- DOI: 10.1007/978-3-031-03873-0_6
Magnetic Resonance Current Density Imaging (MR-CDI)
Abstract
Current density imaging (CDI) was developed with the aim of determining the three-dimensional distribution of externally applied electric current pathways inside a conductive medium, using measurements of magnetic flux density [Formula: see text] data. While the B field may be measurable using instruments such as a magnetometer, in magnetic resonance current density imaging (MR-CDI), an MRI scanner is used to measure the magnetic flux density data induced by current flow. In MR-CDI, the object must be rotated inside the MRI machine to find all three components of the B-field, as only the component of B parallel to the magnet main magnetic field can be measured. In principle, once the all three components of the B field have been obtained from an MR imaging experiment, the current density distribution [Formula: see text] can be reconstructed from Ampere's law [Formula: see text]. However, the need to rotate the object within the MRI scanner limits the usability of this technique. To overcome this problem, researchers have investigated the current density reconstruction problem using only one component of the magnetic flux density Bq, where q = x, y, z. In this chapter, we discuss numerical algorithms developed to reconstruct the distribution of J information from the measured B-field.
© 2022. Springer Nature Switzerland AG.
Similar articles
-
Reconstruction of conductivity and current density images using only one component of magnetic field measurements.IEEE Trans Biomed Eng. 2003 Sep;50(9):1121-4. doi: 10.1109/TBME.2003.816080. IEEE Trans Biomed Eng. 2003. PMID: 12943280
-
Identification of current density distribution in electrically conducting subject with anisotropic conductivity distribution.Phys Med Biol. 2005 Jul 7;50(13):3183-96. doi: 10.1088/0031-9155/50/13/015. Epub 2005 Jun 22. Phys Med Biol. 2005. PMID: 15972989
-
Non-iterative conductivity reconstruction algorithm using projected current density in MREIT.Phys Med Biol. 2008 Dec 7;53(23):6947-61. doi: 10.1088/0031-9155/53/23/019. Epub 2008 Nov 12. Phys Med Biol. 2008. PMID: 19001695
-
MR Current Density and MREIT Data Acquisition.Adv Exp Med Biol. 2022;1380:111-134. doi: 10.1007/978-3-031-03873-0_5. Adv Exp Med Biol. 2022. PMID: 36306096
-
Magnetic resonance electrical impedance tomography (MREIT) for high-resolution conductivity imaging.Physiol Meas. 2008 Oct;29(10):R1-26. doi: 10.1088/0967-3334/29/10/R01. Epub 2008 Sep 17. Physiol Meas. 2008. PMID: 18799834 Review.
References
-
- K. Beravs, D. White, I. Sers̆a, F. Demsar, Electric current density imaging of bone by MRI. Magn. Reson. Imag. 15, 909–15 (1997)
-
- S. Birchfield, Image Processing and Analysis, 1st edn. (Cengage Learning, Boston, 2016)
-
- H.R. Gamba, D.T. Delpy, Measurement of electrical current density distribution within the tissues of the head by magnetic resonance imaging. Med. Biol. Eng. Comput. 36, 165–70 (1998) - PubMed
-
- N. Gao, B. He, Noninvasive imaging of bioimpedance distribution by means of current reconstruction magnetic resonance electrical impedance tomography. IEEE Trans. Biomed. Eng. 55, 1530–38 (2008) - PubMed
-
- C. Göksu, L.G. Hanson, H.R. Siebner, P. Ehses, K. Scheffler, A. Thielscher, Human in-vivo brain magnetic resonance current density imaging (MRCDI). Neuroimage 171, 26–39 (2018) - PubMed
MeSH terms
LinkOut - more resources
Full Text Sources
Medical