Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 Jan 1:224:927-937.
doi: 10.1016/j.ijbiomac.2022.10.178. Epub 2022 Oct 25.

A low-molecular-weight chitosan fluorometric-based assay for evaluating antiangiogenic drugs

Affiliations

A low-molecular-weight chitosan fluorometric-based assay for evaluating antiangiogenic drugs

Cheng-Yu Wang et al. Int J Biol Macromol. .

Abstract

Low-molecular-weight chitosan (LMWCS) damaged cell membranes in zebrafish showed its possibility to release reporter proteins for detection. In this study, we developed a simple fluorometric-based assay for the evaluation of clinical antiangiogenic drugs using LMWCS and Tg(fli1:EGFP) transgenic zebrafish, which expressed green-fluorescence protein (GFP) in the endothelial cells of blood vessel. In vitro stable and transiently transfected cell lines was released luciferase and green fluorescent protein (GFP) for intensity evaluation upon LMWCS fluorometric-based assay. In vivo Tg(fli1:EGFP) transgenic zebrafish was also released GFP from endothelial cells of blood vessels and show an increase of fluorescent intensity upon LMWCS fluorometric-based assay. Treatment with the clinical antiangiogenic drug sorafenib and analyzed by LMWCS fluorometric-based assay showed significantly reduction of angiogenesis. Furthermore, treatment with 2 μM sorafenib showed a significant reduction in angiogenesis of the intersegmental vein (ISV) and dorsal longitudinal anastomotic vessels (DLAV) in Tg(fli1:EGFP) transgenic zebrafish. Fluorescence intensity reduction from 2 μM sorafenib was used as a factor in the LMWCS fluorescence-based assay for relative antiangiogenic evaluation. Relative angiogenesis evaluation of the clinical drugs axitinib, cabozantinib, and regorafenib showed a significant reduction. Collectively, this study provided a simple, convenient, and rapid LMWCS fluorometric-based assay for evaluating angiogenic drugs using transgenic zebrafish.

Keywords: Antiangiogenesis; Drug screening; Fluorometric-based assay; Low-molecular-weight chitosan; Zebrafish.

PubMed Disclaimer

Conflict of interest statement

Conflict of interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

LinkOut - more resources