Hypoxic storage of donor red cells preserves deformability after exposure to plasma from adults with sickle cell disease
- PMID: 36310401
- DOI: 10.1111/trf.17163
Hypoxic storage of donor red cells preserves deformability after exposure to plasma from adults with sickle cell disease
Abstract
Background: Red cell (RBC) transfusions are beneficial for patients with sickle cell disease (SCD), but ex vivo studies suggest that inflamed plasma from patients with SCD during crises may damage these RBCs, diminishing their potential efficacy. The hypoxic storage of RBCs may improve transfusion efficacy by minimizing the storage lesion. We tested the hypotheses that (1) The donor RBCs exposed to the plasma of patients in crisis would have lower deformability and higher hemolysis than those exposed to non-crisis plasma, and (2) hypoxic storage, compared to standard storage, of donor RBCs could preserve deformability and reduce hemolysis.
Study design and methods: 18 SCD plasma samples from patients who had severe acute-phase symptoms (A-plasma; n = 9) or were at a steady-state (S = plasma; n = 9) were incubated with 16 RBC samples from eight units that were stored either under conventional(CRBC) or hypoxic(HRBC) conditions. Hemolysis and microcapillary deformability assays of these RBCs were analyzed using linear mixed-effect models after each sample was incubated in patient plasma overnight at 37°C RESULTS: Relative deformability was 0.036 higher (p < 0.0001) in HRBC pairs compared to CRBC pairs regardless of plasma type. Mean donor RBC hemolysis was 0.33% higher after incubation with A-plasma compared to S-plasma either with HRBC or CRBC (p = 0.04). HRBCs incubated with steady-state patient plasma demonstrated the highest deformability and lowest hemolysis.
Conclusion: Hypoxic storage significantly influenced RBC deformability. Patient condition significantly influenced post-incubation hemolysis. Together, HRBCs in steady-state plasma maximized donor red cell ex vivo function and survival.
Keywords: red blood cells; sickle cell disease; storage lesion.
© 2022 AABB.
Comment in
-
Tools and metrics for the assessment of post-storage performance of red blood cells: no one is left over.Transfusion. 2023 Jan;63(1):1-6. doi: 10.1111/trf.17228. Epub 2022 Dec 20. Transfusion. 2023. PMID: 36537147 No abstract available.
References
REFERENCES
-
- Mohandas N, Gallagher PG. Red cell membrane: past, present, and future. Blood. 2008;112:3939-48.
-
- Lipowsky HH. Microvascular rheology and hemodynamics. Microcirculation. 2005;12:5-15.
-
- Kim-Shapiro DB, Lee J, Gladwin MT. Storage lesion: role of red blood cell breakdown. Transfusion. 2011;51:844-51.
-
- Chin-Yee I, Arya N, d'Almeida MS. The red cell storage lesion and its implication for transfusion. Transfus Sci. 1997;18:447-58.
-
- Hess JR. Red cell changes during storage. Transfus Apher Sci. 2010;43:51-9.