Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 Nov;15(11):1090-1094.
doi: 10.1136/jnis-2022-019273. Epub 2022 Nov 3.

Parent artery occlusion after pipeline embolization device implantation of intracranial saccular and fusiform aneurysms

Affiliations

Parent artery occlusion after pipeline embolization device implantation of intracranial saccular and fusiform aneurysms

Mingyang Han et al. J Neurointerv Surg. 2023 Nov.

Abstract

Background: Studies reporting parent artery occlusion (PAO) after pipeline embolization device (PED) implantation are limited. The aim of this study was to investigate the incidence rate and risk factors of PAO after PED implantation.

Methods: In this retrospective study, we enrolled consecutive patients with intracranial saccular and fusiform aneurysms treated with PED implantation at our institution. Multivariate logistic regression analysis was subsequently performed to determine the risk factors for PAO.

Results: A total of 588 saccular and fusiform aneurysms were finally enrolled in the study. PAO was found in 14 (2.38%) aneurysms. The aneurysm complete occlusion rate was 79.6%. Compared with the non-PAO group, aneurysms in the PAO group were larger in size (20.08 vs 9.61 mm; p<0.001), had a greater neck diameter (9.92 vs 6.15 mm; p=0.001), and had higher frequencies of adjunctive coils (64.3% vs 35.7%; p=0.028). In the multivariate logistic analysis, aneurysm size (OR 1.12, 95% CI 1.02 to 1.24; p=0.016) and the presence of poor wall apposition after balloon angioplasty (OR 7.74, 95% CI 1.28 to 46.82; p=0.026) were associated with PAO occurrence after adjusting for confounding factors.

Conclusions: In this study, the incidence rate of PAO following PED implantation was 2.38% in intracranial saccular and fusiform aneurysms. Aneurysm size and residual presence of poor wall apposition after balloon angioplasty were risk factors for PAO. Further research is required to better understand the mechanisms of PAO.

Keywords: Aneurysm; Brain; Complication; Stent.