Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2022 Oct 3;14(10):e29852.
doi: 10.7759/cureus.29852. eCollection 2022 Oct.

Incidence of Flexor Tendon Injuries in Complex Intra-Articular Distal Radius Fractures Fixed With Volar Rim Plate Osteosynthesis

Affiliations

Incidence of Flexor Tendon Injuries in Complex Intra-Articular Distal Radius Fractures Fixed With Volar Rim Plate Osteosynthesis

Wei Siong Chua et al. Cureus. .

Abstract

Aim: The volar rim plate is anatomically contoured to provide buttressing of distal radius fragments including the lunate fossa. The low-profile design of the plate minimizes flexor tendon irritation. This study aims to determine the Disabilities of the Arm, Shoulder, and Hand (DASH) score and the presence of flexor tendon irritation at around one-year post operation.

Method: Between June 2020 and May 2021, all patients with AO-23B3 and AO-23C (1-3) distal radius fractures who were treated with a volar rim plate fixation were included in this study. At 12 months after surgery, the patients were evaluated utilizing DASH score as a routine as well as evidence of flexor tendon rupture or irritation.

Results: Twenty-five patients were finally included in this study. Of these, three required additional dorsal plating for dorsal subluxation, four required fixation of ulna styloid with tension band wiring, and the rest (18) had volar rim plate fixation in isolation. The mean DASH score was 16.3. Two of the patients had flexor tendon irritations; one in the middle finger and another in the ring and little finger. None had flexor tendon rupture.

Conclusion: The volar rim plate is designed to tackle complex intra-articular distal fractures which are near the watershed line. There was no evidence of flexor tendon irritation on routine follow-up. The outcome was satisfactory in this small series despite the complexity of the fractures. Evidence of flexor tendon irritation requires prompt attention to enable early implant removal.

Keywords: distal radius; flexor tendon irritation; flexor tendon rupture; malay dash questionnaire; malaysia; volar rim.

PubMed Disclaimer

Conflict of interest statement

The authors have declared that no competing interests exist.

Figures

Figure 1
Figure 1. An example of AO 23C3 distal radius fracture treated with volar rim fixation by addressing the lunate fossa fragment

References

    1. Midterm follow-up of treating volar marginal rim fractures with variable angle LCP volar rim distal radius plates. Goorens CK, Geeurickx S, Wernaers P, Staelens B, Scheerlinck T, Goubau J. J Hand Surg Asian Pac Vol. 2017;22:184–187. - PubMed
    1. Fragment-specific volar hook plate for volar marginal rim fractures. Bakker AJ, Shin AY. Tech Hand Up Extrem Surg. 2014;18:56–60. - PubMed
    1. Distal radius volar rim fracture fixation using depuy-synthes volar rim plate. Kachooei AR, Tarabochia M, Jupiter JB. J Wrist Surg. 2016;5:2–8. - PMC - PubMed
    1. Prevent collapse and salvage failures of the volar rim of the distal radius. Orbay JL, Rubio F, Vernon LL. J Wrist Surg. 2016;5:17–21. - PMC - PubMed
    1. Flexor tendon complications in comminuted distal radius fractures treated with anatomic volar rim locking plates. Kara A, Celik H, Oc Y, Uzun M, Erdil M, Tetik C. Acta Orthop Traumatol Turc. 2016;50:665–669. - PMC - PubMed

LinkOut - more resources