Clinical utility of ultrasonography, pulse oximetry and arterial line derived hemodynamic parameters for predicting post-induction hypotension in patients undergoing elective craniotomy for excision of brain tumors - A prospective observational study
- PMID: 36339752
- PMCID: PMC9634272
- DOI: 10.1016/j.heliyon.2022.e11208
Clinical utility of ultrasonography, pulse oximetry and arterial line derived hemodynamic parameters for predicting post-induction hypotension in patients undergoing elective craniotomy for excision of brain tumors - A prospective observational study
Abstract
Background: Hypotension, which is a common adverse effect of induction of anesthesia, may be especially detrimental in neurosurgical patients. Hence, it is important to investigate hemodynamic parameters which may be useful in identifying patients at risk of hypotension, following induction. Our study was designed to assess the utility of parameters derived from ultrasonography, pulse oximeter and arterial line for predicting post-induction hypotension.
Methods: The study was designed as a prospective, observational trial. Written informed consent was obtained from 100 American Society of Anesthesiologists (ASA) 1 and 2 patients, between 18-60 years of age, scheduled for elective craniotomy for brain tumors. Arterial cannula was inserted before induction of anesthesia and connected to Vigileo cardiac output monitor. Baseline stroke volume variation (SVV), stroke volume (SV), cardiac index (Ci), cardiac output (CO) and pulse pressure variation (PPV) were recorded. Plethysmography variability index (PVI) and perfusion index (PI) were obtained from the Masimo rainbow SET® Radical-7® pulse oximeter. Ultrasonographic assessment of the inferior vena cava (IVC) was performed before induction of anesthesia and again within 15 min after induction. Maximum and minimum IVC diameters (dIVCmax and dIVCmin) and collapsibility index (CI) were measured. All the other aforementioned parameters were recorded every minute starting at induction, until the 15th minute following induction.
Results: PI, CI and dIVCmax were found to have the largest AUCROC for the prediction of post-induction hypotension (AUCROC 0.852, 0.823 and 0.781 respectively). Multiple logistic regression analysis revealed CI to be the most significant independent factor for the prediction of post-induction hypotension.
Conclusion: Non-invasively derived hemodynamic parameters like dIVCmax, CI and PI were more accurate for the prediction of post-induction hypotension, compared to invasively derived parameters.
Keywords: Collapsibility index; Hypotension; Perfusion index; Plethysmographic variability index; Ultrasonography.
© 2022 The Author(s).
Conflict of interest statement
The authors declare no conflict of interest.
Figures
References
-
- Zhang J., Critchley L.A.H. Inferior vena cava ultrasonography before general anesthesia can predict hypotension after induction. Anesthesiology. 2016 Mar;124(3):580–589. - PubMed
-
- Tommasino C. Fluids and the neurosurgical patient. Anesthesiol. Clin. 2002 Jun;20(2):329–346. vi. - PubMed
-
- Marshall L.F., Becker D.P., Bowers S.A., Cayard C., Eisenberg H., Gross C.R., et al. The national traumatic coma data bank. Part 1: design, purpose, goals, and results. J. Neurosurg. 1983 Aug;59(2):276–284. - PubMed
-
- Juri T., Suehiro K., Tsujimoto S., Kuwata S., Mukai A., Tanaka K., et al. Pre-anesthetic stroke volume variation can predict cardiac output decrease and hypotension during induction of general anesthesia. J. Clin. Monit. Comput. 2018 Jun;32(3):415–422. - PubMed