. 2023 Jan 1:370:338-344.
doi: 10.1016/j.ijcard.2022.10.160. Epub 2022 Oct 29.

Prevalence and prognostic impact of tricuspid regurgitation in patients with cardiac implantable electronic devices: From the national echocardiography database of Australia

Affiliations

Prevalence and prognostic impact of tricuspid regurgitation in patients with cardiac implantable electronic devices: From the national echocardiography database of Australia

Sophie Offen et al. Int J Cardiol. .

Abstract

Aims: We sought to analyse the distribution of TR severity and survival in a large cohort of adults with CIED leads.

Methods: The distribution of TR severity was analysed in 18,797 adults (mean age 73.8+/-13.9, 63.3% men) with CIED leads undergoing echocardiography across 25 centres. Survival status and cause of death were linked and the relationship between TR severity and mortality during 2.6 (interquartile range 1.1-4.6) years follow-up examined. Data from 439,558 individuals (mean age 62.1 ±17.8 years, 51.5% men) without a CIED were subsequently incorporated in a pooled cohort analysis.

Results: Overall, 8,824/18,797 individuals (47%) with a CIED had no/trivial TR; 5,490 (29.2%) mild TR; 3,068 (16.3%) moderate TR; and 1,415 (7.5%) severe TR. Moderate or greater TR was independently associated with age, female sex, atrial fibrillation and significant left heart disease (p<0.001 for all). 8,868 individuals (47.2%) died from any cause (43.2% from cardiovascular causes). Individuals with moderate or severe TR had a 1.6 to 2.5-fold increased risk of all-cause mortality in adjusted models, compared to those with no TR (p<0.001 for both). In the pooled cohort analysis, CIEDs were associated with a near 2-fold (95% CI 1.81-1.99; p<0.001) increased probability of moderate or greater TR, on adjusted basis. However, the mortality associated with moderate or greater TR did not differ significantly with respect to the presence or absence of a device lead.

Conclusions: Moderate or greater TR is more prevalent in those with CIED's, even in adjusted models, and was independently associated with incremental risks for all-cause and cardiovascular mortality.

Keywords: Cardiac Implantable Electronic Device; Echocardiography; Tricuspid Regurgitation.