. 2023 Aug;74(3):570-581.
doi: 10.1177/08465371221137885. Epub 2022 Nov 8.

Interobserver Variability and Accuracy of Preoperative CT and MRI in Pancreatic Ductal Adenocarcinoma Size Estimation: A Retrospective Cohort Study

Affiliations

Interobserver Variability and Accuracy of Preoperative CT and MRI in Pancreatic Ductal Adenocarcinoma Size Estimation: A Retrospective Cohort Study

Romain Cocquempot et al. Can Assoc Radiol J. 2023 Aug.

Abstract

Purpose: To assess interobserver variability and accuracy of preoperative computed tomography (CT) and magnetic resonance imaging (MRI) in pancreatic ductal adenocarcinoma (PDAC) size estimation using surgical specimens as standard of reference. Methods: Patients with PDAC who underwent preoperative CT and MRI examinations before surgery were included. PDAC largest axial dimension was measured by 2 readers on 8 MRI sequence and 2 CT imaging phases (pancreatic parenchymal and portal venous). Measurements were compared to actual tumour size at pathologic examination. Interobserver variability was assessed using intraclass correlation coefficients (ICC) and Bland-Altman plots. Differences in tumour size (Δdiameter) between imaging and actual tumour size were searched using Wilcoxon rank sum test. Results: Twenty-nine patients (16 men; median age, 70 years) with surgically resected PDAC were included. Interobserver reproducibility was good to excellent for all MRI sequences and the 2 CT imaging phases with ICCs between .862 (95%CI: .692-.942) for fat-saturated in-phase T1-weighted sequence and .955 (95%CI: .898-.980) for portal venous phase CT images. Best accuracy in PDAC size measurement was obtained with pancreatic parenchymal phase CT images with median Δdiameters of -2 mm for both readers, mean relative differences of -9% and -6% and no significant differences with dimensions at histopathological analysis (P = .051). All MRI sequences led to significant underestimation of PDAC size (median Δdiameters, -6 to -1 mm; mean relative differences, -21% to -11%). Conclusions: Most accurate measurement of PDAC size is obtained with CT images obtained during the pancreatic parenchymal phase. MRI results in significant underestimation of PDAC size.

Keywords: Computed Tomography; Magnetic Resonance Imaging; Observer Variation; Pancreatic Ductal Carcinoma; Reproducibility of Results.

PubMed Disclaimer

Conflict of interest statement

Declaration of Conflicting InterestsThe authors declare no potential conflicts of interest with respect to the research, authorship, and/or publication of this article.